HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online Page 1 of 2
RECEIV7-D ,A,N 7017
e t
SCIS Home I Log in I User Registration ( Hat Topics I Submit Surcharge Stats&Facts Publications FI3C Staff I SCIS Site Flap Links I Search
dbpr
a
Product Approval
USER:Public User
Product aporovaP Menu>Product or Auoli[atlon Search>Aanliratlnn Lis t>Applreation Delait
FL it FL10626-1112
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archivedi ❑
Product Manufacturer GAF
Address/Phone/Emaif 1 Campus Drive
Parisppany,NJ 07054
(973)872-4421
tindareith@trinityerd.com
Authorized)Signature Beth McSorley
lindarelth@trinityerd.com
Technical Representative Beth McSorley(current)
Address/Phone/Email1 Campus Drive
Parsippany,N3 07054
(973)872-4421
bmcsorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory U'nderlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
2 Evaluation Report-Hardcopy Received
Florida,Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 11/12/2017
Validated By John W.Knezevich,PE
10 Validation Checklist-Hardcopy Received
Certificate of Independence FL10626 R12 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM D6164 2005
ASTM D6757 2007
FM 4474 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
Equivalence of Product Standards
Certified;By
Ih!ttp://www.filoridabuilding.org/pr/pr app_dti.aspa?param=wGEVXQwtDgtBNbEY5V%2... 9/21/2016
Florida Building Code Online Page 2 of 2
Sections from the Code
Product Approval Method Method i Optfon D
Date Submitted, 03/31/2015
Date Validated 04/08/2015
Date Pending FBC Approval 04/12/2015
Date Approved! 06/23/2015
Summary of Products
FL# Model,Number or Name Description
110626.1 GAF Roof Underrayments Roofing underlayments for use in sloped roof systems
Limits of Use Installation Instructions
Approved for use in,HVHZ:No FLI0626 R12 II 2015 03 FINAL ER GAF Underlavments FL10626-
Approved for use outside HVHZ:Yes R12.Ddf
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:+N/A/-45.0 Created by Independent Third Party:Yes
Other:1.)The design pressure noted In this Evaluation Reports
application relates to one particular underlayment FL10626 R12 AE 2015 03 FINAL ER GAF Underlavments FL2D626-
systerm for use under foam-on tide systems.Refer R12.DdF
to-ER Section 5.6.4 for details.2.)Refer to ER Created by fndependent Third Party:Yes
Section,5 for other Limits of Use.
back Next.
Contact Us.::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Coovri0h[2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail]to this entity.Instead,contact the office by phone or by traditional malt.If you have any questions;please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a.personal.address,please provide the Department with an email address which can be made available to the public.To determine if you are a licence under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
92® ethaV M
Credit Card
Safe
llfltp.//www-flal,tdabuildirrng.org/pr/pr_app_dtl.aspx?param wGEVXQwtDgtBNbEYSV%2... 9/21/2016
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
N STREET, UNIT 413 0TRINrry ERD 353 CHRISTIAOXFORD,Cr 06478
PHONE:(203) 262-9245
FAX:(203) 262-9243
EVALUATIONREPORT
GAF Evaluation Report 01506.04.08-1112
1Cam'pus Driue FLiQ626-1112
Parsippany,M91 0+7054 Date of Issuance:04/25/2008
Revision 12:03/31/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in.the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
R.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products, described herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Roof Underlayments
LABELING: Labelling shall he in accordance with the requirements the Accredited Quality Assurance Agency noted
herelm
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
QuallityAssurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this. Eval'uatiicntn Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes,or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADvERTISENIEN'II:The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in
advertising,literature. if any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
Its distributors and shall be available for inspection at the job site at the request of the Building Official.
This-Evaluation Report consists of pages 1 through 8.
Prepared:by:
a-
47_
r}� :� Vl7 The facsimile.seal appearing,Tearing was tauthorizedserve
by Robert Nieminen,
Robert J.M.N1'aeminen,P.E. ••;TF:�%>:�{er :;� P.E.on 03/31/2015,This does rro[serve as an electronlca0y signed
Florida RegistratliQn No.59266;Florida DCA'ANE2983 {,•,, ,t;{'�P.•� document.Signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION,OF INDEPENDENCE:
11. TrinityllERD does not have,nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing;products it evaluates.
21. TrinitylIERDI os not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
I. Robert NietmlJnen,.P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which theevoluation reports are being issued.
4.. Robert NieminerT,P-E.d'oes not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product..
5.. This is a bu0ing,code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are,in any way,the Designer of Record for any
project on whfch this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
a
rTRINIW ERD
ROOFING COMPONENT.EVALUAT.IOW
1. SCOPE:
Product Category.- Roofing
Sub-Category: Underlayment
Compliance Statement: GAF Roof Underlayments, as produced by GAF, have demonstrated compliance with the following
sections of the Florida,Building Code through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.31.1 Wind!Uplift FM 4474 2004
1507.2.44 1507.2.9.2,1507.5.3, Physical Properties ASTM D1970 2009
1507..7.3
1507.2.3 Physical Properties ASTM D6757 2007
1507.1122 Physical'iProperties ASTM D6164 2005
1523.6.5,2.1 Physical!Properties TAS 103 1995
1507.3.3', Installation Practice FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
lentity Examination Reference Date
ERD(TST 6049): Physical Properties G12210.06.09 08/03/2009
ERDI(TST6049) Physical'.Properties G34150.08.11 11/14/2011
ERD(TST 6049)1 Physical Properties G40630.01.14-2B 01/07/2014
ERD,(TST604% Physical'.Properties G46160SC 04/14/2014
PRI(.TST 5878) Physical'properties GAF-026-02-01 03/26/2002
PRI;(TST 5878): Physicat properties GAF-027-02-D3 03/26/2002
PRI,(MST Physicalproperties GAF-042-02-02 03/12/2004
PRI,(TiST-5878)i Physical properties GAF-042-02-01 06/03/2005
PRI,(TiST3878) Physical properties GAF-I54-02-01 02/06/2007
PR1i(TST'5878)'� Physical properties RGM-023-02-01 02/09/2007
PRI!(TST 5878) Physical properties. ELK-311-02-01 09/11/2007
PRI(TST 58781, Physical properties GAF-238-02-03 03/03/2010
PRI:(TST 58781i Physical properties GAF-275-02-01 11/11/2010
PRI.(TST 5878) Physical properties GAF-349-02-01 06/19/2012
PRI(TST 58781; Wind Uplift GAF-434-02-01 09/16/2013
PRIi(:TST 5878)' Wind Uplift GAF-434-02-03 09/16/2013
PRU(TiST 5878) Wind Uplift GAF-434-02-04 09/16/2013
ITS(TST1509) Physical properties 3077464-002 09/14/2005
ITS,(TiST 1509). Physicatproperties 3077464-02 01/09/2006
UL(TST 1740) Physicall properties 02NK22569 06/04/2002
UL(TST IrP40), Physical properties IONK11990 05/18/2011
MamwDade(CER 1592) HVHZcompliance 13-1104.05 02/20/2014
Miami,Dade(CER 1592) HVHZcompliance 13-1104.11 03/06/2014
Miami�Dade(CER 1592), HVHZcompliance 14-1022.26 02/05/2015
ICC-ES(EVL2396) IBC compliance ESR-1322 01/01/2014
UL,LLC.(QUA 9625) Quality Control Inspect,File R10689,Stockton,CA 11/12/2014
UL,LLC.(QUA 9625) Quality Control Inspect,File R10689,Hickory,NC 03/04/2015
UL',.LLC.(QUA 9625) Quality Control Inspect,File R10689,Mt.Vernon,IN 01/16/2015
UL,.LLC.(QUA 9625) Quality ControlInspect,File R10689,Pryor,OK 02/05/2015
4. PRODU'C'T DESCRIPTION:
4.1 Self-Adhering Undertayments:
4.1-1 Lr-berty'"SBS Self-Adhering Base/Ply,Sheet is a smooth-surfaced,fiberglass-reinforced,self-adhering SBS modified
bitumen roof undertayment.
4.1.2' StormGuard`"Films Surfaced Leak Barrier is a film-surfaced,fiberglass-reinforced,self-adhering SBS modified bitumen
roof underfayment. StormGuard® Film Surfaced Leak Barrier is also used as a secondary water barrier to seal roof
decks..
Exterior Research and Design,LLC. Evaluation Report 01506.04.08-R32
Certifmte ofAathorization#9503 FL10626-1112
Revision 12:03/31/2015
Page 2 of 8
OTP.-INITY ERS
4.1.3 UnderRoof"2 Polyester-Surfaced Leak Barrier is a spun-bond-glass-reinforced-polyester-mat-surfaced,composite-
reinforced,565self-adhering modified bitumen roof underlayment.
4.1.4 UnderRoofr"HT High Temperature Leak Barrier is a polyester-mat-surfaced,fiberglass-reinforced,self-adhering SBS
modified bitumen roof underlayment.
4.11.5. Me"'a,'bt29K;W_1'o ce3 5rr¢faaerdCdeaic axruar=`is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen roof underlayment. WeatherWatch® Mineral Surfaced Leak Barrier is also used as a secondary
water barrier to seat roof decks.
4.1.6 WeatherWatch® XT Mat Surfaced Leak Barrier is a coated-mat-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen roof underlayment.
4.2 Mechanically Fastened Underlavments:
4.2.1 VersaShfe1&Fire-Resistant Roof Deck Protection is a non-asphaltic,fiberglass-based roof underlayment and/or fire
barrier.
4.3 Asphalt-Applied Underlayments:
4'.3-1 Ruberoid® Mop Granule is,a granule-surfaced, polyester-reinforced, asphalt-applied SBS modified bitumen roof
underlayment.
4.3,2' Ruberoid'9 Mop Granule FR (formerly Ruberoid°Mop 170 FR) is a granule-surfaced, polyester-reinforced, asphalt-
applied SBS modified bitumen roof underlayment.
5. LIM6TASIONs.
5.1 This is a building code evaluation. Neither TrinityEERD nor Robert Nieminen,P.E. are,in any way,the Designer of
Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory or test
report from accredited testing agency for fire ratings of this product.
5.4 GAF Roof Underla.yments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval; documents. If not listed, a request may be made to the AHJ for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.5. Allowable roof covers applied atop GAF Roof Underlayments are follows:
" 'TAotE,l:rRooFCOvii R'OPTIONS
Asphalt Wood Shakes& Slate or
Underla�tment Shingles Nail-On life Foam-On Tile Metal Shingles Simulated Slate
VersaShield'Fire-Resistant Yes No No No No No
Roof Deck Protection
Liberty-SBS Self-Adhering Yes No No No No No
Base/Ply Sheet
StormGuard°Fitm.Surfaced
Leak Barrier Yes i No No Yes No No
UnderRoofr 2 Polyester- Yes
Surfaced,Leak Barrier Yes Yes See 5.5.1 No No Yes
Und'erRoof"HT High
Yes No No Yes No No
Temperature Leak Barrier
' av9Warriec— L,f"f.o.>M "0- -1 3
r
WeatherWatch°XT Mat Yes No No No No No
Surfaced Leak Barrier
Ye
' Ruberoid®Mop Granule Yes Yes See5y5.1 No Yes Yes
Yes
Ruberoid'Mop Granule FR Yes Yes No Yes Yes
See S.S.I
Exterior Research and Design,LLC. Evaluation Report 01506.04.08-R32
Certificate ofAuthorization#9503. FL10626-1112
Revision 12:03/31/2015
Page 3 of 8
TRINITY I ERD
5.5.1 "Foam-On Tile"is limited to use of the following unless tensile adhesion/long term aging data from an accredited
testing laboratory is provided.
Underfayment(s) Adhesive Option(s)
Und'erRoof"2 Polyester-Surfaced Leak Barrier 3M"2-Component Roof Tile Adhesive AH-160(FL633:2)
! R'uberoW Mop Granule;RuberoW Mop Granule FR Dow TfleBond(FL717)
5.6 Allowable substrates are noted below:
Liberty'" SBS Self-Adhering? Base/Ply Sheet; StormGuard° Film Surfaced Leak Barrier; UnderRoof" 2 Polyester-
Surfaced Leak Barrier; Und!erR'oof`" HT High Temperature Leak Barrier; T�feat erWatchm�Mgne�alESuficedrLeak�J
1tgirigand WeatherWatch°XT Mat Surfaced Leak Barrier,Self-Adhered to Deck: A
➢ New untreated plywood!;
➢ Fxistfng untreated ASTM D41 primed plywood.
Ruberoid°Mop Granule and Ruberoid°Mop Granule FR,Asphalt-Applied to Deck:
Y ASTM.D41 primed structural)concrete.
5.6.2 Liberty:- SBS, Self-Adhering: Base/Ply Sheet; StormGuard° Film Surfaced Leak Barrier; UnderRoof'" 2 Polyester-
Surfaced Leak Barrier; UnderRoof" HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced Leak
Barrier and WeatherWatch® XT Mat Surfaced Leak Barrier. Self-Adhered to Mechanically Attached Base
U'nderl'ayment:
➢ ASTM'.D226,Type II felt.
➢ StormSafe'"Anchor Sheet
Ruberoid® Mop Granule and Ruberoid® Mop Granule FR, Asphalt-Applied to Mechanically Attached Base
Underl'ayment:
L' GA FG LAS"#80 Ultima'"Base Sheet;
Y Ruberoid®20 Smooth.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on the systems, base layer shall be attached per minimum
requirements of FRSA/TRf Apri,[2022(04-12)or as detailed below.
5.6.3 Bond!to Other Substrate Types:
➢ ASTM D41 primed metal(flashing metal,valley metal,etc.)
5.6,4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed In FRSA/TRI April 2012(04-12)and are used in foam-on tile applications.. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure
divided, by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for
determination of design wind load's.
5.6:.4.1 Maximum Design Pressure=-45 psf.
Deck: Min 15/32-inch plywood to meet project requirements to satisfaction of AHI.
Primer: (Optional)ASTM D41
U'nd'erlayment:. UnderRoof"'2 Polyester-Surfaced Leak Barrier,self-adhered
5•.64.2 Maximum,Design Pressure=-45 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: GAFGLAS®#80 Ultimaj'Base Sheet or Ruberoid®20 Smooth mechanically attached with 12 ga.,min.
1.25-inch long ring shank nails through 32 ga.,1-5/8 inch diameter tin caps spaced 9-inch o.c.at the
4-inch wide side laps and 9-inch o.c.at two(2),equally spaced,staggered center in the field of the
sheet.
Top Layer: Ruberoid° Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 lbs/square.
Exterior Research and Design;LLC. Evaluation Report 01506.04.08-1112
Certificateof Authorization#9503 FL10626-1112
Revision 12:03/31/2015
Page 4 of 8
TRINI-rf ERD
5.6.4.3 Maximum Design Pressure=-45 psf.
Deck- Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: GAFGLAS°#80 Ultima'"Base Sheet or Ruberoid®20 Smooth mechanically attached with 12 ga.,min.
1.25-inch long ring shank nails through 32 ga.,1-5/8 inch diameter tin caps spaced 8-inch o.c.at the
4-inch wide side laps and 8-inch o.c.at three(3),equally spaced,staggered center in the field of the
sheet.
Top Layer: Ruberoid'°Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 lbs/square.
5.7 Exposure Limitations:
5.7.1 Liberty'" SBS Self-Adhering Base/Ply Sheet; StormGuardm Film Surfaced Leak Barrier; UnderRoof'" HT High
Temperature Leak Barrier;WeatherWatch°Mineral Surfaced Leak Barrier and WeatherWatch°XT Mat Surfaced Leak
Barrier shall not be left exposed for longer than 30-days after installation.
5.7 2, VersaShield" Fire-Resistant Roof Deck Protection, UnderRoof" 2 Polyester-Surfaced Leak Barrier, Ruberoid" Mop
Granul''e and'Ruberoid®Mop Granule FR shall not be left exposed for longer than 180-days after installation-
6. iNSTALLATI'ON:
6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
anyd'ust and debris prior to application,and prime the substrate(if applicable).
6.3 I'nstal'l self-adhering underlayments when ambient temperatures are minimum 45°F and rising.
6.4 All metal,surfaces shalt be primed with Matrix'"307 Premium Asphalt Primer or alternate GAF accepted ASTM D41
primer prior to application of self-adhering membranes.
6.5 VersaShield®Fire-Resistant Roof Deck Protection:
6.5.1 Install)VersaShierd® Fire-Resistant Roof Deck Protection in compliance with manufacturer's published installation
instructions and the requirements for ASTM D6757 underlayment in FBC Section 1507.2.3 for the type of prepared
roof covering to be installed. A double layer is required for 2:12<roof slope<4:12. No hammer tacks*or staples are
permitted
6.5.2 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty'" SBS Self-Adhering
Base/Ply Sheet; StormGuard" Film Surfaced Leak Barrier; UnderRoof" 2 Polyester-Surfaced Leak Barrier;
UnderRoof" HT High Temperature Leak Barrier; WeatherWatch° Mineral Surfaced or WeatherWatch'D XT Mat
Surfaced Leak Barrier at vulnerable teak areas, including but not limited to eaves, valleys, rakes, skylights and
dormers. At eaves and valleys,install the leak barrier prior to installation of the underlayment. Along the rake,
install] the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the
und'erla•yment and exposed decking. At other areas,install the leak barrier over the underlayment.
6.6. Liberty"SBS Self=Adhering.Base/Pty Sheet:
6.6..1 Ihstalll Liberty" SBS Self-Adhering Base/Ply Sheet in compliance with manufacturer's published installation
instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof
covering to be installed.
6.6.2 The minimum and maximum roof slopes are%2:12 and 6:12,respectively. Back-nailing is required when slope is 1:12
or greater. Back-nailing shall'consist of minimum 1-inch square or round cap nails spaced 18"o.c.within 3-inch side
laps.
6.6.3 For non-til'e applications,direct to deck:
For direct-bond to deck applications plywood shall be primed with Matrix"307 Premium Asphalt Primer or alternate
GAF accepted ASTM D41 primer at%to%gallon per square.
Prior to removal of release film,align sheets properly starting at the low-point of the roof(eave)with the selvage
edge upstope and for minimum 2-inch overhang at eaves and rakes. Roll out sheet and allow to'relax'for min. 30
minutes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the
eave and nail into place 12"o.c. Remove the top piece of release film and bond to substrate. Install primed drip
edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of Matrix'"201 Premium
SBS Flashing Cement over drip edge.
Exterior Research and Design,LLC. Evaluation Report 01506.04.08-1112
Certificate'of Authorizotiorr#9503 FL10626-R12
Revision 12:03/31/2015
Page 5 of 8
TRININ I ERD
Continue upslope in a similar manner,maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Ensure
all!end Paps are staggered at least 18-inch apart.
Use a weighted!lawn or linoleum roller to ensure complete adhesion to the substrate. Use a hand roller to firmly
bond'-side and end laps.
6:6.4 For non-tile applications to mechanically attached anchor sheet:
Installs ASTM D226,Type II felt in accordance with codified requirements or StormSafe'"Anchor Sheet in accordance
with,Section 6:6.
Install Liberty"SBS Self-Adhering Base/Ply Sheet over the mechanically attached anchor sheet as noted above.
6.7 StormGuard"Film Surfaced Leak Barrier:
6.7.1 Install StormGuard°Film Surfaced Leak Barrier in compliance with manufacturer's published installation instructions
and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to
be installed.
6.7.2 Back-nailing is required- Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c.
within 3-inch side laps.
6.7.3For non-til'e applications,direct to deck:
Prior to removal of release film,align sheets properly starting at the low-point of the roof(eave)with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and
bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load
requirements. Install'1/8-inch troweling of Matrix"201 Premium SBS Flashing Cement over drip edge.
Continue upslope in a similar manner,maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Ensure
alf end Paps are staggered at least 18-inch apart.
Use a hand roller to firmly bond side and end laps.
6.7.4 For non-tile applications,to mechanically attached anchor sheet:
Install ASTMI D226,Type IF felt in accordance with codified requirements or StormSafe"Anchor Sheet in accordance
with Section G.G.
Install StormGuard®Film.Surfaced Leak Barrier over the mechanically attached anchor sheet as noted above.
6.8, UnderRoof—2 Polyester-Surfaced Leak Barrier:
6.3.1 Install UnderRool" 2 Polyester-Surfaced Leak Barrier in compliance with manufacturer's published installation
instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof
covering to be installed.
6.8.2 The minimum and maximum roof slopes are 2:12 and 12:12,respectively. Back-nailing is required when slope is 4:12
or greater. Back-nailing shall'consist of minimum 1-inch square or round cap nails spaced 12"o.c.within 4-inch side
Paps.
6.813' For tile roof.installations:.
Reference is made to FRSA/TRI April 2012 (04-12) installation Manual and Table 1 herein, using the instructions
noted herein as a guideline. Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to
the und'erl'ayment.
6.8.4 For non-tile applications,direct to deck:
Prior to removal of release film,align sheets properly starting at the low-point of the roof(eave)with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and
bond,to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load
requirements. Pnstall'1/8-inch troweling of Matrix"201 Premium SBS Flashing Cement over drip edge.
Continue upslope in a similar manner,maintaining minimum 4-inch side-laps and minimum 6-inch end-laps. Ensure
all ends laps are staggered at least 3-feet apart. End laps shall be sealed with a 1/16`h to 1/8'h inch thick trowel
application of Matrix'"201 Premium SBS Flashing Cement.
Use a hand roller to firmly bond side and end laps.
Exterior Research and Design,LLC_ Evaluation Report 01506.04.08-R32
Certificate-of AWthorization.#9503 FL10626-R12
Revision 12:03/31/2015
Page 6 of 8
TOR IWry I ERD
6:8'.5 For non-tile applications,to mechanically attached anchor sheet:
install ASTM!D226,Type fli felt in accordance with codified requirements or StormSafe'"Anchor Sheet in accordance
with Section,6.6.
Install UnderRoof"2 Polyester-Surfaced Leak Barrier over the mechanically attached anchor sheet as noted above.
6.9' UnderRoof"HT High Temperature Leak Barrier:
6.9.1 Install UnderRoof- HT High Temperature Leak Barrier in compliance with manufacturer's published installation
Instructions andi the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof
covering.to be installed.
6.9..2 The minimum and maximum roof slopes are 1:12 and 12:12,respectively. Back-nailing is required when slope is 4:12
or greater. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 12"o.c.within 4-inch side
Paps.
6.9'.3 For non.-tlfe applications,direct to deck:
Prior to:removal of release film, align sheets properly starting at the low-point of the roof(eave)with the selvage
edge ups[ope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and
bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film. and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load
requirements. Install 1/8-inch troweling of TopCoat"FlexSeal'"Caulk Grade over drip edge.
Continue upslope in a similar manner,maintaining minimum 4-inch side-laps and minimum 6-inch end-laps. Ensure
all end laps are staggered at least 3-feet apart.
Use a hand]rollerto firmly bond'side and end laps.
6.9.4 For non-tire applications,to mechanically attached anchor sheet:
Install:ASTM D226,Type 11 felt in accordance with codified requirements or StormSafe'"Anchor Sheet in accordance
with Section 6.7.
Install UnderRoof"HT High Temperature Leak Barrier over the mechanically attached anchor sheet as noted above.
WetherWatchP-MirretalSurfacediteak'Biiri&...or-Uffeather9dtfatcK!I*XfMat SurfacedLeak,Barrier::
6.10111 lnstalli WeatherWatch®Mineral Surfaced Leak Barrier or WeatherWatch®XT Mat Surfaced Leak Barrier in compliance
with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC
Sections 1507 for the type of prepared roof covering to be installed.
6.10.2' WeatherWatch° Mineral Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-inch
wide rolls to sea[plywood deck joints prior to installation of the primary underlayment system.
6.1013 Back-nailing is required. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c.
within 4-inch side laps.
6.10.4 For non4il'e applications,direct to deck:
Prior to removal of release film, align sheets properly starting at the low-point of the roof(eave)with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and
bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film amd bond to substrate. instal[ primed drip edge and fasten to meet FBC Chapter 16 wind load
requirements. Install 1/8-inch troweling of Matrix"201 Premium SBS Flashing Cement over drip edge.
Continue upslope in a similar manner,maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Ensure
all'end Paps are staggered at least 18-feet apart.
Use a.hand roller to firmly bond side and end laps.
6.1015 For non-tile applications,to mechanically attached anchor sheet:
I'mstall ASTM D226,Type ll felt in accordance with codified requirements or StormSafe'"Anchor Sheet in accordance
with Section 6.6.
Install'WeatherWatch Mineral Surfaced Leak Barrier or WeatherWatch® XT Mat Surfaced Leak Barrier over the
mechanically attached anchor sheet as noted above.
Exterior Research and Design*UC. Evaluation Report 01506.04.08-R32
Certificate of Authorization#9503 FL10626-1112
Revision 12:03/31/2015
Page 7 of 8
��TRINITYIERD
6.11. Ruberoid®Mop Granule;Ruberoid®Mop Granule FR:
611.1 Shall" be installed in compliance with current GAF published installation requirements, subject to the limitations
herein.
6.11.2 N'on-Tile Applications:
6.11.2.1 Fully adhere in ASTM D312,Type IV hot-asphalt to the substrates noted in Section 5.5. Side laps shall be minimum 4-
inch and end-Paps minimum,64nch wide,and offset end-laps minimum 3-feet from course to course. Side and end-
laps,shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch
beyond the lap edge. Consult GAF instructions regarding back-nailing requirements.
6.11.3• Tile Applications:
6.113.1 Refer to FRSA/FRI!April 2012(04-12)Installation Manual and Table 1 herein.
6.11.3.2 Tile.shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment-
7.. BUILDMIS PERMIT REQUIREMENTS:
As required by the Building Official'or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8.. MANUFACTURING PLANTS:
Comtactthe manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 OA requirements.
9. QUALI nv AssUR'ANCE Eivvm.
UL,L'LC.—QU'A9625;(847).664-3281,
END OF EVALUATION REPORT-
Exterior Research,and Design,LLC. Evaluation Report 01506.04.08-1112
Certificate•af Ahtharizatiarr#9503 FL10626-R12
Revision 12:03/31/2015