Loading...
HomeMy WebLinkAboutEngineering r PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone (772) 785 - 9888 E-mail pwelchinc@aol.com January 17,2017 Re: Withers Rel Roof 741 Nettles Blvd. Jensen Beach, FL 34957 a j SCOPE OF WOUK: Install new Metal Roof(Extreme Metal Fabricators,LLC "5-V Crimp"FL#17022.1)at above referenced addressl over new underlayment, and existing plywood sheathing. DESIGN CRITERIA: FBC 2014 j a ASCE?-10 PROJECT DATA: BUILDING HIEGHT= 10'-0" A=3' MEAN ROOF HIEGHT=<15' ROOF ANGLE=4:12 SHAPE=PITCHED GABLE ADJUSTMENT FACTOR= 1.00 RVIPROTANCE FACTOR= 1.00 WIND VELOCITY V ult= 165MPH WIND VELOCITY V asd= 128 MPH EXPOSURE=D ENCLOSURE CLASS=ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 APPLIED UPLIFT DESIGN PRESSURES PER ASCE (PSF)• ZONE 1 (Field)_X40.3 ZONE 2 (Perimeter/Ridge)_-68.0 ZONE 3 (Corners) -99.8Paul Welch Inc. Plaul Welch P.E. Reg.No. 29945 January 17, 2017 a 741 Nettles Blvd Jensen Beach,FL 1 6f3 i I I I METAL ROOFING ATTACHMENT REOUIREMENTS: Metal roofing to be attached with corrosion resistant Hex-Head(wood screws,#10 z 1 minimum with weather sealing washers(minimum 3/16"penetration through deck). Fasteners shall be placed through the panel ribs at 12"on center across panel width and spacing along the ribs as follows: ZONE 1 (Field): FASTENER SPACING= 16" O.C. ZONE 2(Perimeter/Ridge): FASTENER SPACING= 16"O.C. ZONE 3 (Corners) FASTENER SPACING=8" O.C. NOTE:PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER13 VERT. :12 HORZ. i Design uplift Pressure for attachment as per above: Product Design Pressure: Zones 1 &2: 93.5PSF/Zone 3: -101PSF Therefore O.K. I UNDERLAYMENT: Underlayment shall be in accordance with manufacturer's guidelines, FBC 1507.4.5.1, and FBC 15074.5.2.Underlayment shall be Tri-Built underlayment NOA# 15-1123.06. DECK INSTALLATION: Re-nail all plywood sheathing(15/32"thick minimum)with 8D ring-shank nails at 4"O.C. perimeter and 6" 6,C. field for all zones. All work to be in compliance with product approval (FL# 17022.1), (NOA#i 15-1123.06.), manufacturer s specifications, and the Florida.Building Code 2014. N Paul Welch Inc. Paul Welch P.E. Reg.No.29945 January 17,2017 741 Nettles Blvd Jensen Beach,FL 2.6f 3 i i ._............. .- ---- - - - - - I p ' i • N S LO Pr i� i �lLd ti I �l i( �y i ► il Ij A A •A A ROOF ZONE PLAN 'A=3' ZONE DESIGNATION(TYPICAL) NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER13 VERT. :12 HORZ. i . Paul Welch Inc. Paul Welch P:E. Reg.No. 29945 January.l7, 2017 741 Nettles Blvd Jensen Beach,FL 3 of 3 i