HomeMy WebLinkAboutProduct Approval (2) R,ECFI',_D !AN 1 -.i ? 1
SilverLine
ff`i
4"
byAndersen _ J=a
�N m
WINDOWS • DOORS Z1
.111�11a N••
O
SERIES 3600 MODEL 3601/3611 Kto 9 m`W
E ❑a p o a
50.0"MAx.O.A. \v a N a m
EXTRUDEDVINYL FIN TOFIN WIDTH ? oZ
TILT DOUBLE HUNG WINDOW f 46.�1 •a•A ^1 �W
FRAME WIDTH o
LL A
w/ NAILING FIN
3 fn Z
"IMPACT' ' 3 �_
v W
^ J ��
GENERAL NOTES = w w
This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building m Z5
Code(FBC)structural requirements including the"High Velocity Hurricane Zone"(HVHZ). z LL o o w
q o
a
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material o
shall be beyond wall dressing or stucco. }
D b a]
3. When used in the"HVHT'this product complies with section 1626 of the Florida Building Code and does X
not require an impact resistant covering. / m
Z 4. When used in areas outside of the"HVHT'requiring wind bome debris protection this product complies
o with Section 1609.1.2 of the FBC and does not require an impact resistant covering.This product meets z
missile level"D"and includes Wind Zone 4 as defined in ASTM El 996 and Section 1609.1.2.2 of the FBC. LL
- W o
� I
5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck
emasonry construction.
a 6. Site conditions that deviate from the details of this drawing require further engineering analysis by a a
licensed engineer or registered architect. =
N
7. This product meets water infiltration requirements for'TiVHZ". t �2
w Z
0 o
- n
TABLE OF CONTENTS °S:OVERA(1 - -MAX. - - - MAX - '=DESIGN PRESSURE(PSI), -z i
SHEET DESCRIPTION FIN FRAME. D.LO.'. GLASS
a 1 Typical elevations,design pressures&general notes DIMENSION- DIMENSION DIMENSION TYPE POSITIVE, NEfATIVE- DATE:10/24/13 i
2 Horizontal and vertical cross sections +50.0 50.0 SCALE: N.T.S. 9
50.0"X 76.0" 46.0"X 72.0" 40.06"X 32.19" G 1,G2
3 Horizontal and vertical cross sections DWG.BY: JK m
A. 4 Buck and frame anchoring
CHK.aY: LFS 3
5 Components DRAWING NO.:
6 Bill of materials&glazing details
FL-14996.7 4
0
SHEET_L DF 6 N
V
f.
K
R:\Clients Silverline Buildina Products-P Florida Product A royals FL-14996 Double Hun C-Drawin s FL 14996 2014 FL-14996.10-.14.dw 14-2
a v v v a v
v
0
V Gl
D pg p
W �
N 3
N N IA o
X00 1
O IA IA N
A
a
0 �
n _
V
O
O —z
Z �� O
R
CD m
O
O� a°
Wa
a °
o
ID
°
IIIIIIIINIMMMM o.$
° 0.
,4 Oa
4< 4° 3 w
m < a x
x
T O
� m
°
� a
rn
0)
U� N
r0
N N Cn
D
cn
oO� a. <
O^ U\
70 DO o N O
n
O gn
T D W V
[�) DD rn 10 ti
O N m 4
Z ° o _ Q
m
v 0
D-
1-1/4"MIN.
EMB.(TYPJ
1F`Sc 'tf
T PRODUCT: Doeuments Pmpared By:�
Lyndon F. Schmidt '�j�•• (''
n t DOUBLE HUNG WINDOW P.E. No. 43409 1,17111
SS`
o '7111 1DIYAI. ��
IN a o Z� m 111111111111 ,
N PART OR ASSEMBLY: BUILDING CONSULTANTS, INC.
IT in 1 3 18 15 UPDATE TO 5TH ED. (2014) FBC X J V�P.O. Box 230, Valrtco, FL 33595
° w NO DATE BY HORIZONTAL & VERTICAL CROSS SECTIONS phone No.: 813.859.9197
REVISIONS FBPE C.A. No. 9813
0 2013 R.W.BUILDING CONSULTANTS INC.
R:\Clients\Silverline Buildinq Products- Florida Product A rovals\FL-14996 Double Hun C-Drawin s\FL 14996 2014\FL-14996.10-.14.dw,14-3
Q o oma°
O V
A
W
�
� A N
5O o A
2n A
o
� n
O �
V
Z
O O 7 N ry
Z 0 0 0 m
0) ao
wo
a
a(D
o CL
r_ a
�Do
o-
a
o =
0 3
N
O
P-
0 0
` rn N a
DO L4 r_
� N
W A> to
ao ole 0�
aO Q
n�
n
0 n
LT), Ilu
i-
on
DO O7
0.
�O
y oo D N to
W
0 D W
Z N 10 m
m
Z
38
Is,CH41,0'7�7i
j � No.43409
PRODUCT: Document. Prepared By:'i
F x P n L ndon F. Schmidt ��j�'•
r o DOUBLE HUNG WINDOW P E. No. 43408
\ m ��nnnnar
o " y .Np PART OR ASSEMBLY: �K BUILDING
in\ 1 3 18 15 UPDATE TO 5TH ED. (2014) FSC JK J l� P.O. Box CONSULTANTS, INC.
230, Valrico, FL 33595
O1 j, x W NO DATE BY HORIZONTALSECTIONSCAL CROSS Phone No.: 81 3.659.9197
REVISIONS I FBPE C.A. No. 9813
2013 R.W.BUILDING CDNSU-NTS INC.
i
a �O 'So
�
2X FRAMING TO BE DESIGNED
BY THE ENGINEER OR ARCHFIECT Z �l�` m
OFR BASED ON WIND LOADS w•'
_ AND THE CLADDING BEING USED. ��� ,•�,C, o m
(TYP,.O.C. -+{ 7, S'MAX.O.C. '� ��trlt*F'tt���Y~` a n 0 i '
--
(TYP-) ///))) TYP. (fYP,.) t $ a x zo-
•V�. 4 v U o
2„ . Z m U
TYP. a N j d r a
c d
C `0:
Y
K TYP. �d
D TYP. 2X BUCK j J TYP.
t d O— d U
2X BUCK 0: O o
o Z U
MEETING '-
RAIL F. 3 LU
X w
MASONRY d MASONRYF --1 4
OPENING OPENING T F
(1)THRU FRAME T U
ti' 'el MIDSPAN OF ,
a EACHJAMB tij THRU FRAME of m
®MIDSPAN OF
°1 FRAME EACH JAMB a I
m FRAME }}
m
a
4
N �
v Z
BUCKANCHORING FRAME ANCHORING FRAMEANCHORING w
2X buck construction r Stud construction CQNCREfEANCHORNOTES: m i
1.Concrete anchor locations at the comers may be adjusted to maintain the min. 100
edge distance to mortarjoints. <
2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to
r; maintain the min,edge distance to martar joints,additional concrete anchors
o may be required to ensure the"MAX,ON CENTER"dimension are not exceeded. m
m 3.Concrete anchor table: -LU z
a
mQ
- o
� ANCHOR ANCHOR MIN MIN.CLEARANCE: MIN:CLEARANCE
� z
TYPE SIZE EMBEDMENT ., TO MASONRY TOADJACENT
EDGE' ANCHOR z aITW °
V PC ouE:16124113 z
$ TAPCON� 1/4' T-i/4" 2" q" o i
sc&E: N.T.S.
o ELCO 5
ULTRACON® 1/4" 1.1/4" 1" 4" owc.Br: JK m
m 3 WOOD SCREW INSTALLATION NATES: CHK.SY: LFSoRaw �
I.Maintain a minimum SIF edge distance,I"end distance,&I"D.C.spacing of lHc ao.: m
wood screws to prevent the splitting of wood. FL-14996.14 a
SHEET 4 OF 6
r
R-.\Clients\Silverline Building Products-%Florida Product Approvals\FL-14996 Double Hung\C-Drawings\FL 14996(2014)\FL-14996.10-.14.dwg,14-5
2.59"
F+1.557' 2 y ?
2 Ln
m
c ooL
7'
�O y 0.0
0.73'
m>
2 N
z
0
V �{ 1.435' r ?
T
A T in
2
y
H
2.05"
70
A T
TIN
0.51" n1.545'-
r.01 t T171I
o
F56P]
0.05'
A
a�
so
90
0.84"
0
s
11+7
y Z
1.557'� co
Gl
D N H
E3 t9
A "
--►{ 1.435"
O I T}
IJV � I
n y V
D m
0
��•��v•�vc�ivaF••.T .�
/ No.43408 '
D PRODUCT: DooumentB PrePerod ey:��
t" Lyndon F. Schmidt ,,, �(.�
I� \ DOUBLE HUNG WINDOW P.E. No. 43409
to o ''7is�QIVALI
o - y PART OR ASSEMBLY: �K BUILDING CONSULTANTS, INC.
1 —3/-11371-5 UPDATE 70 5TH ED. (2014) FBC JK COMPONENTS J l� P.O. Box 230, Valrico, FL 33595
y C, NO DATE BY Phone No.: 813.859.9197
REVISIONS FBPE CA No. 9813
'02013 R.W.8UILDING C-6—A—B INC.
BILL OF MATERIALS . *It%
ITEM B DESCRIPTION MATERIAL � A, .-a-A 2X FRAMING SG>=0.42 WOOD =at o 'j'B 2X BUCK SG>=0.42 WOODD 114"X 2-3/4"PFH ELCO OR TTW CONCRETE SCREW STEEL Ni 7 ZMASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI c E301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE yF #10 X 2"FH WOOD SCREW STEEL 1/7'GLASS 7/8"OVERALL GLASS THK. i1 ' * ��% m M m iG 1/4"MAX SHIM SPACE BITE ILII I0 N '.
J #8 X 2"PPH SMS(1-3/4-MIN.EMBEDMENT) STEEL 20 40 1/8"ANNEALED GLASS c� p i o z L)
K #S X 1-1/7'PPH SMS(1-314-MIN.EMBEDMENT) STEEL \ N a v v 9 0 o a
1 EXTRUDED PVC MAIN FRAME HEAD/JAMB#52-3001' PVC V m 'G.t m
2 EXTRUDED PVC MAIN FRAME SILL#52-3003` PVC 0.090"DuPONT BUTACITE® sa
3 HEAD ADAPTER#50 9522(6063 T6) ALUMINUM PVB INTERLAYER o Z
4 EXTRUDED PVC GLAZING BEAD#1227* PVC 1/8"ANNEALED GLASS
�w
5 EXTRUDED PVC UPPER LIFT RAIL#52-8506` PVC AIR SPACE
6 EXTRUDED PVC UPPER SASH BOTTOM RAIL#52-8507PVC
7 EXTRUDED PVC UPPER SASH STILES#52-8504` PVC Q } o J
8 EXTRUDED PVC LOWER SASH TOP RAIL#52-8508' PVC =
9 EXTRUDED PVC LOWER LIFT RAIL#52-8506' PVC 37
10 EXTRUDED PVC LOWER SASH STILES#52-8505` PVC 4 1/8"ANNEALED GLASS
12 UPPER SASH KEEPER STEEL J �
GT GLAZING DETAIL Lu
13 LOWER SASHLOCK STEEL w
14 #8-32 X 1/2"PPH MS STEEL
16 PILE WEATHERSTRIP W/FIN " o 0 m
18 BULB SEAL Q-LON 0
19 UPPER SASH LATCH PVC 1/Z'GLASS 7/8"OVERALL GLASS THK. a a
BITE20 GLAZING SILICONE(DOW 995) SILICONE 40
GO
0 21 UPPER SASH TILT LATCH(NOT SHOWN) PLASTIC 20 1/8 ANNEALED GLASS
22 UPPER SASH PIVOT BAR(NOT SHOWN) STEEL
28 #8 X 1"PFHSCREW STEEL
0.090"DuPONT BUTACITE
29 #6 X 1"PFH SCREW ZINC PLATED STEEL PVB INTERLAYER a
31 SASH LOCK ASSY(DIE CAST ZINC ALUMINUM) 1/8 ANNEALED GLASS N N
32 SASH LOCK KEEPER(ZINC DIE CAST)
z
34 KEEPER RAIL&STILE REINFORCEMENT#50-9523 ALUMINUM AIR SPACE w s
-il35 LIFT RAIL REINFORCEMENT#50-9530 ALUMINUM L
- 36 LOCK RAIL REINFORCEMENT#50-9529 ALUMINUM Q R
o
37 GLAZING SPACER(INTERCEPT) STEEL
< 43 GLAZING SILICONE(TREMCO S7000) SIUCONE
o 43
GLAZING SPACER SUPERSPACER) PVC 4 43
1/
40 GLASS i
_ G2 GLAZING DETAIL �� a I
'a
- , THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BEn
PRODUCED BY EXTRUDERS LICENSEES IN "AAMA CERTIFICATION PROGRAMS FOR RIGID n z
PVC EXTRUSIONS".
DAm 10/24/13 i
SCALE: N.T.S. °
CHK.BY. LFS 3
DRAWING NO.:
FL-14996.14 m
m
SHEET_L OF 6 N
V
K
R W R W Building Consultants, Inc.
BConsulting and Engineering Services for the Building Industry
C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197
Florida Board of Professional Engineers Certificate of Authorization No.9813
Product Evaluation Report // I ///
Iat&:, APHIZ 2015,
Product Sub Category Manufacturer Product Name
Category
Silverline Building Products Series 3600 Model 360113611
Windows Double Hung 1 Silverline Drive Extruded Vinyl
North Brunswick,NJ 08902 Tilt Double Hung Window w1 Nailing Fin
Phone-732.435.1000 "Impact'
Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc.and Lyndon F.Schmidt, P.E.(System ID#
1998)for Silverline Building Products based on Rule Chapter No.61 G20-3,Method 1 D of the State of Florida Product
Approval,Department of Business&Professional Regulation.
RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of the product named
herein.
Limitations:
1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code(FBC)structural requirements
includinq the"High Velocitv Hurricane Zone"(HVHZ).
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in the"HVHZ"this product complies with Section 1626 of the Florida Building Code and does not require an impact
resistant covering.
4. When used in areas outside of the"HVHZ"requiring wind borne debris protection this product complies with Section 1609.1.2 of the
2010 FBC and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined
in ASTM E1996.
5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction.
6. Site conditions that deviate from the details of drawing FL-14996.14 require further engineering analysis by a licensed engineer or
registered architect.
7. This product meets the water infiltration requirements for"HVHZ".
8. See drawing FL-14996.14 for size and design pressure limitations.
Supporting Documents:
1. Test Report No. Test Standard Testing Laboratory Signed by
ATI C7606.03-109-18 TAS 201,202&203-94 Architectural Testing, Inc. Michael D.Stremmel, P.E.
Materials PVC Extrusions
ETC 97-26440910 ASTM D635-96,D1929-96, D2843-93 ETC,Laboratories J.L.Doldan, P.E.
D638-96 and G26-95
2. Miami-Dade NOA Materials Testing
13-0129.27 PVB Interlayer by DuPont
3. Drawing No. Prepared by Signed&Sealed by
No.FL-14996.14 RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt,P.E.
4. Calculations Prepared by Signed&Sealed by
Anchoring RW Building Consultants, Inc. (CA#9813) Lyndon F.Schmidt,P.E.
ASTM E1300 Glass Load Lyndon F. Schmidt,P.E. "=; s
5. Quality Assurance X 's
Certificate of Participation issued by Window&Door Manufacturers
Association,certifying that Silverline Building Products Corporation is
manufacturing products within a quality assurance program that complies.
with ISOIIEC 17020 and Guise 53.
s r'
'1
Lyndon F.Schmidt,P.E.
FL PE No.43409
412812015
Sheet 1 of 1
NOTICE OF PRODUCT CERTIFICATION
CERTIFICATION NO: NI011202-R1
DATE: 07/25/2012
m x CERTIFICATION PROGRAM: Structural
sc ,�
COMPANY: T.M. Window
CODE: T-829-1
-'QE,►;E.,T` -. REVISION DATE: 02/27/2015
FlEO pno
To verify that the"Notice of Product Certification"is valid,please visit www.NAMlCerti I ication.com to assure that the
product is active and currently listed.This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
T. M. Windows,LLC Series "DH93WW Unequal Glass"
1543 N.Powerline Road PVC Double Hung Window
Pompano Beach, FL 33069
Configuration:X/X
Glazing: Insulating Glass(Annealed)
Frame: W-1372mm(54") H-2134mm(84")
Sash: W-1289mm(50.75") H-1059mm(41.69")
SPECIFICATION PRODUCT RATING
AAMA/WDMA/CSA 101/I.S.2/A440-08 Class LC-PG70 1372 x 2134 (54 x 84)-H
Design Pressure: 3360 Pa (70 psf)
Water Penetration Resistance Test Pressure:580 Pa(12.12 pso
Product Tested By: Architectural Testing, Inc.
Report No: A8440.03-501-47/A8440.02-501-47
Expiration Date: June 30,2019
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes,VA 23072
Tel: (804)684-5124
Fax: (804)684-5122
NOTICE OF PRODUCT CERTIFICATION
C IF��q '
CERTIFICATION NO: N1011210-R1
DATE: 07/25/2012
CERTIFICATION PROGRAM: Structural
COMPANY: T.M. Window
CODE: T-829-1
' ►�,eo P�fla� REVISION DATE: 02/27/2015
To verify that the"Notice of Product Certification"is valid,please visit www.NANIICertification.com to assure that the
product is active and currently listed.This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
T. M. Windows,LLC Series "DH93WW/Sloped"
1543 N. Powerline Road PVC Double Hung Window
Pompano Beach, FL 33069
Configuration:X/X
Glazing: 1/8"Annealed Glass/Laminate-
1/8"Annealed Glass/0.090"DuPont Butacite PVB/
1/8"Annealed Glass
Frame: W-1372mm(54") H-2134mm(84")
Sash: W-1286mm(50.63") H-1057mm(41.63")
SPECIFICATION PRODUCT RATING
ASTM E1886-05/E1996-05 Design Pressure: +70/-70 psf
Wind Zone 3-Missile Level D
Product Tested By: Architectural Testing, Inc.
Report No: B0829.01-501-47
Expiration Date: June 30,2019
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes,VA 23072
Tel: (804)684-5124
Fax: (804)684-5122
L. Roberto Lomas P.E. Engineering Evaluation Report
233 W.Main St
Danville,VA 24541 Report No.: 512283A
434-688-0609
rlloiiias@lrloiTiaspe.com
Irlomaspe.com
Manufacturer: TM Windows L.L.C.
1543 North Powerline Rd.
Pompano Beach, FL 33021
Product Line: Series"DH93WW Unequal Glass"PVC Double Hung Window Reinforced-LMI
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a).The product listed
herein complies with requirements of the Florida Building Code
Supporting Technical Documentation:
1. Approval document: drawing number 08-01618 Revision B, prepared,signed and sealed by Luis Roberto
Lomas P.E.
2. Report No.:A8440.03-501-47 signed by Lynn George
Architectural Testing Laboratories, Springdale, PA
AAMA/WDMA/CSA 101/i.S.2/A440-08
Design pressure: ±70.Opsf
Water penetration resistance 12.2psf
3. Report No.: 80829.01-501-44 signed by Lynn George
Architectural Testing Laboratories, Springdale, PA
ASTM E1886-05 and ASTM E1996-05
ASTM E1886/E1996 Large Missile Impact, Level D,Wind Zone 3
ASTM E1886/E1996 Cyclic Load Test, ±70.Opsf design pressure
4. Anchor calculations, report number 512283-1, prepared,signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure: ±70.Opsf
• Maximum unit size: 54"x 84"
• Units must be glazed per ASTM El 300-04, see installation instructions for glass details.
• This product is not rated to be used in the HVHZ.
• This product is impact resistant and does not require impact protection in wind borne debris regions, up to wind
zone 3.
• Frame material to be rigid PVC.
Installation: Units must be installed in accordance with approval document, 08-01618 Revision B
Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company
manufacturing or distributing the product(s)for which this report is being issued.Also, I don't have nor will acquire a
financial interest in any other entity involved in the approval process of the listed product(s).
\�� i
CP
;* 0 51
TATE OF ;t�
��
• . . . -
V,
/iss/4NA� E�G�
/rnlll
1 of 1 Luis R. Lomas, P.E.
FL No.:62514
02/27/2015
R W R W Building Consultants, Inc.
B Consulting and Engineering Services lbr the Building Industry
C P.O.Box 23U Valrico,FL 33595 Phone 813.659.9197
Florida Board orProlicssional Engineers Certificate orAnihorizition No.9813
Product / Report Report IFL-14996.14
Aprill
Product Sub Category Manufacturer Product Name
Category
Silverline Building Products Series 3600 Model 360113611
Windows Double Hung 1 Silverline Drive Extruded Vinyl
North Brunswick,NJ 08902 Tilt Double Hung Window w/Nailing Fin
Phone-732.435.1000 "Impact"
Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc.and Lyndon F.Schmidt, P.E.(System ID#
1998)for Silverline Building Products based on Rule Chapter No.61G20-3,Method 1D of the State of Florida Product
Approval,Department of Business&Professional Regulation.
RW Building Consultants and Lyndon F.Schmidt, P.E.do not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of the product named
herein.
Limitations:
1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code(FBC)structural requirements
including the"High Velocity Hurricane Zone"(HVHZ).
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in the"HVHZ"this product complies with Section 1626 of the Florida Building Code and does not require an impact
resistant covering.
4. When used in areas outside of the"HVHZ"requiring wind borne debris protection this product complies with Section 1609.1.2 of the
2010 FBC and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined
in ASTM E1996.
5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction.
6. Site conditions that deviate from the details of drawing FL-14996.14 require further engineering analysis by a licensed engineer or
registered architect.
7. This product meets the water infiltration requirements for"HVHZ".
8. See drawing FL-14996.14 for size and design pressure limitations.
Supporting Documents:
1. Test Report No. Test Standard Testing Laboratory Signed by
ATI C7606.03-109-18 TAS 201,202&203-94 Architectural Testing, Inc. Michael D.Stremmel,P.E.
Materials PVC Extrusions
ETC 97-26440910 ASTM D635-96,D1929-96,D2843-93 ETC,Laboratories J.L. Doldan, P.E.
D638-96 and G26-95
2. Miami-Dade NOA Materials Testing
13-0129.27 PVB Interlayer by DuPont
3. Drawing No. Prepared by Signed&Sealed by
No.FL-14996.14 RW Building Consultants, Inc.(CA 49813) Lyndon F.Schmidt, P.E.
4. Calculations Prepared by Signed&Sealed by
Anchoring RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt, P.E.
ASTM E1300 Glass Load Lyndon F.Schmidt,P.E.
5. Quality Assurance
Certificate of Participation issued by Window&Door Manufacturers
Association,certifying that Silverline Building Products Corporation is
manufacturing products within a quality assurance program that complies
with ISO/IEC 17020 and Guise 53.
Lyndon F.Schmidt,P.E.
FL PE No.43409
4/28/2015
Sheet 1 of 1
The Home Depot Special Order Quote
�., Customer Agreement#: H0213-26255 , f
Printed Date:1/17/2017`
Customer Information Store Information
Name LORALYNNE SCHNEIDER Store Number 0213
Address 7605 PENSACOLA RD FORT PIERCE FL Address 1885 58TH AVE
PA41PIERCE, FL 34951 VERO BEACH, FL 32966
Primary Phone 443-825-9155 Associate JAMES
Secondary Phone 443-825-9155
ffi�6J�l � ,} (Q�g��je _ �.fL•di..kI4. '�_.._..__._ _nE
100-1 Series 9650 Double Hung 36.125 x 60.5 - $716.07 4 $2,864.28
Frame Width=36.125
Frame Height=60.5
Sash Split=Even
SKU=1000030331
Vendor Name=TM Window
Vendor Number=60074855
Manufacturer=TM Window
Customer Service=1-954-781-4430
Catalog Version Date=3/4/16
Lead Time=28 Days
Room Location=Custom
Custom Location=sewing room
Code Version=Code Version
Florida Building Code=15804.1
Screen=Full Screen
Exterior Finish=White
Interior Finish=White
Maximum Design Pressure=DP+/-70
Glass Thickness=1"
Glass Strength=Annealed
Glass Interlayer=PVB
Product Approval Glass Code=VP DH
Meets Energy Star Requirements=Yes
Meet Turtle Code=No
Low-E=High Performance Low-E(Cardinal 366)
ti----- 361.'8 -i
Argon Gas=Yes
Glass Tint=Clear
Frame Type=Box Frame with 5/8"Snap-on Flange
Snap-On Interior Frame Accessory=Frame Plug
Meets HVHZ Requirements=No
Meet 2014 FBC Energy Requirements=Yes
Climate Zone=Zone 1&2
Glass Type=Insulated Impact
Lock Type=Sweep Lock
Overall Frame Width=36.125
Overall Frame Height=60.5
Overall TipToTip Width=37.125 _
Overall TipToTip Height=61.5
e,5 &d) ZlrrA)
www.HomeDepot.com Page 1 of 11 Printed By: JAMES /17/2017 2:14 PM
P (�
n
200-1 Bay Mull Bar Accessory Other - $225.73 2 $451.46
SKU=1000030342
Vendor Name=TM Window
Vendor Number=60074855
Manufacturer=TM Window
Customer Service=1-954-781-4430
Catalog Version Date=3/4/16
Lead Time=10 Days
Include Mull Clips=Yes
Mull Clip=Bay Mull Clip-Qty:2
Mull Series=45 Degree Bay Mull
Mull Width&Height=3.163"x 3.432"
Mull Wall Thickness=1/4"
Engineering Document Included=Yes
Mull Bar Length=60.5
Two Tone Color Finish=No
Exterior Finish=White
Interior Finish=White
Finish Type=Standard Paint
Finish Warranty=1 Year Coastal/3 Year Inland Warranty
300-1 Aluminum Mull Bar Accessory Other - $87.84 1 $87.84
SKU=1000030342
Vendor Name=TM Window
Vendor Number=60074855
Manufacturer=TM Window
Customer Service=1-954-781-4430
Catalog Version Date=3/4/16
Lead Time=10 Days
Code Version=Code Version
Florida Building Code=13188.2
Meets HVHZ Requirements=Yes
Include Mull Clips=Yes
Mull Clip=1"x 4" Mull Clip-Qty:2
Mull Clip Screw Pack=For Non-Casement Windows
Mull Series=Rectangular w/Exterior Vinyl Cap
Mull Width&Height=1"x 4"
Mull Wall Thickness=1/8"
Mull Bar Length=60.5
Two Tone Color Finish=No
Exterior Finish=White
Interior Finish=White
Finish Type=Standard Paint.
Finish Warranty=1 Year Coastal/3 Year Inland Warranty
www.HomeDepot.com Page 2 of 11 Printed By: JAMES Date Printed: 1/17/2017 2:14 PM
l 'In° 9;�(a o:`�?. i _ Rf�.4 Ati �l 7j �( lr'tn j..... __ t
400-1 70 Series NFJ Impact Double-Hung-36011MPACT - rc 2 $
36.125 x 60.5 $555.30 $1,110.60
Installation Zip Code=34951
U.S.ENERGY STAR®Climate Zone=Southern Save$196.00(15%) until 1/18/2017
ENERGY STAR Required=No *S/0 SILVER LINE BLDG PRD-260803 Promotion
Standard Width=Custom until 1/18/2017
Standard Height=Custom
Frame Width=36 1/8
Frame Height=601/2
Exterior Color=White
Interior Finish Color=White
Performance Grade(PG) Rating=PG50
Glass Construction Type=Dual Pane
Glass Option=Low-E Sun Argon
High Altitude Breather Tubes=No
Glass Strength=Impact Resistant _
Glass Tint=No Tint `D
Specialty Glass=None c
Gas Fill=Argon
None
Number of Sash Locks=Double
Lock Type=Standard
Insect Screen Type=Full Screen
Insect Screen Material=Fiberglass
Foam=No
J-Channel Filler=Yes
Extension Jamb Type=None
Re-Order Item=No
i 36 118
Room Location=Custom Location
Custom(Enter Room Name)=sewing room ►--- RO-36 518 -- --i
Unit U-Factor=0.31
Unit Solar Heat Gain Coefficient(SHGC)=0.21
U.S.ENERGY STAR Certified=Yes
Florida Product Approval Number(FL#)=14996
High Velocity Hurricane Zone(HVHZ)=Yes
SKU=260803
Vendor Name=S/0 SILVER LINE BLDG PRD
Vendor Number=60660514
Customer Service=(888)888-7020
Catalog Version Date=11/18/2016
www.HomeDepot.com Page 3 of 11 Printed By: JAMES Date Printed: 1/17/2017 2:14 PM
500-1 70 Series NFJ Impact Double-Hung-36011MPACT - 5 2 $1,152.10
26 x 60.5 $489.64 $979.28
Installation Zip Code=34951
U.S.ENERGY STAR®Climate Zone=Southern Save$172.82(15%) until 1/18/2017
ENERGY STAR Required=No *S/0 SILVER LINE BLDG PRD-260803 Promotion
Standard Width=Custom until 1/18/2017
Standard Height=Custom
Frame Width=26
Frame Height=601/2
Exterior Color=White
Interior Finish Color=White
Performance Grade(PG) Rating=PG50
Glass Construction Type=Dual Pane _
Glass Option=Low-E Sun Argon
High Altitude Breather Tubes=No
Glass Strength=Impact Resistant
Glass Tint=No Tint `D Iz!
Specialty Glass=None c
Gas Fill=Argon
None
Number of Sash Locks=Double
Lock Type=Standard
Insect Screen Type=Full Screen
Insect Screen Material=Fiberglass
Foam=No
J-Channel Filler=Yes
Extension Jamb Type=None
Re-Order Item=No
�- 25 -i
Room Location=Living Room
Unit U-Factor=0.31 t- RO-26 112 i
Unit Solar Heat Gain Coefficient(SHGC)=0.21
U.S. ENERGY STAR Certified=Yes
Florida Product Approval Number(FL#)=14996
High Velocity Hurricane Zone(HVHZ)=Yes
SKU=260803
Vendor Name=S/0 SILVER LINE BLDG PRD
Vendor Number=60660514
Customer Service=(888)888-7020
Catalog Version Date=11/18/2016
www.HomeDepot.com Page 4 of 11 Printed By: JAMES Date Printed: 1/17/2017 2:14 PM
" " °� �o o An)){ h�i r ry il --
600-1 70 Series NFJ Impact Double-Hung-36011MPACT - r` 23 ?�8
25.5 x 60.5 $485.69 $971.38
Installation Zip Code=34951
U.S.ENERGY STAR®Climate Zone=Southern Save$171.40(15%)until 1/18/2017
ENERGY STAR Required=No *S/0 SILVER LINE BLDG PRD-260803 Promotion
Standard Width=Custom until 1/18/2017
Standard Height=Custom
Frame Width=25 1/2
Frame Height=60 1/2
Exterior Color=White
Interior Finish Color=White
Performance Grade(PG) Rating=PG50
Glass Construction Type=Dual Pane
Glass Option=Low-E Sun Argon \,r7
High Altitude Breather Tubes=No
Glass Strength=Impact Resistant
Glass Tint=No Tint
Specialty Glass=None
Gas Fill=Argon
None
Number of Sash Locks=Double
Lock Type=Standard
Insect Screen Type=Full Screen
Insect Screen Material=Fiberglass
Foam=No
J-Channel Filler=Yes
Extension Jamb Type=None
Re-Order Item=No
25 112Room Location=Living Room ~ �
Unit U-Factor=0.31 t RO-26 ----s
Unit Solar Heat Gain Coefficient(SHGC)=0.21
U.S. ENERGY STAR Certified=Yes
Florida Product Approval Number(FL#)=14996
High Velocity Hurricane Zone(HVHZ)=Yes
SKU=260803
Vendor Name=S/0 SILVER LINE BLDG PRD
Vendor Number=60660514
Customer Service=(888)888-7020
Catalog Version Date=11/18/2016
www.HomeDepot.com Page 5 of 11 Printed By: JAMES Date Printed: 1/17/2017 2:14 PM
taLCx3_ �ra=
700-1 70 Series NFJ Impact Single-Hung-29011MPACT - Y $366.48a1 &S
24.5 x 36.75 $311.50 $311.50
Installation Zip Code=34951
U.S. ENERGY STAR®Climate Zone=Southern Save$54.98(15%)until 1/18/2017
ENERGY STAR Required=No *S/0 SILVER LINE BLDG PRD-260803 Promotion
Standard Width=Custom until 1/18/2017
Standard Height=Custom
Frame Width=24 1/2
Frame Height=36 3/4
Exterior Color=White
Interior Finish Color=White
Performance Grade(PG) Rating=PG50
Glass Construction Type=Dual Pane
Glass Option=Low-E Sun Argon
High Altitude Breather Tubes=No
Glass Strength=Impact Resistant
Glass Tint=No Tint r
Specialty Glass=Obscure cry
Gas Fill=Argon C;
None
Hardware Color/Finish=White
Number of Sash Locks=Single
Lock Type=Standard
Window Opening Control Device=Factory Applied
Window Opening Control Device Color=White
Insect Screen Type=Half Screen
Insect Screen Material=Fiberglass 24 1/2
Foam=No i Raj -25
Drywall Return=No
J-Channel Filler=Yes
Extension Jamb Type=None
Re-Order Item=No
Room Location=Bathroom#2
Unit U-Factor=0.33
Unit Solar Heat Gain Coefficient(SHGC)=0.23
U.S. ENERGY STAR Certified=Yes
Florida Product Approval Number(FL#)=14911
High Velocity Hurricane Zone(HVHZ)=Yes
Clear Opening Width=19.5
Clear Opening Height=12.908
Clear Opening Area=1.747958
SKU=260803
Vendor Name=S/0 SILVER LINE BLDG PRD
Vendor Number=60660514
Customer Service=(888)888-7020
Catalog Version Date=11/18/2016
www.HomeDepot.com Page 6 of 11 Printed By: JAMES Date Printed: 1/17/2017 2:14 PM
800-1 70 Series NFJ Impact Single-Hung-29011MPACT $389.9B 1 $389.93
35.25 x 36.5 $331.44 $331.44
Installation Zip Code=34951
U.S.ENERGY STAR®Climate Zone=Southern Save$58.49(15%) until 1/18/2017
ENERGY STAR Required=No *S/O SILVER LINE BLDG PRD-260803 Promotion
Standard Width=Custom until 1/18/2017
Standard Height=Custom
Frame Width=35 1/4
Frame Height=36 1/2
Exterior Color=White
Interior Finish Color=White
Performance Grade(PG) Rating=PG50
Glass Construction Type=Dual Pane
Glass Option=Low-E Sun Argon
High Altitude Breather Tubes=No
Glass Strength=Impact Resistant
Glass Tint=No Tint
Specialty Glass=None o CD
Gas Fill=Argon m
None
Hardware Color/Finish=White
Number of Sash Locks=Double
Lock Type=Standard
Window Opening Control Device=No
Insect Screen Type=Half Screen 35 V4
Insect Screen Material=Fiberglass f-- RO-35 314
Foam=No
Drywall Return=No
J-Channel Filler=Yes
Extension Jamb Type=None
Re-Order Item=No
Room Location=Garage
Unit U-Factor=0.33
Unit Solar Heat Gain Coefficient(SHGC)=0.23
U.S.ENERGY STAR Certified=Yes
Florida Product Approval Number(FL#)=14911
High Velocity Hurricane Zone(HVHZ)=Yes
Clear Opening Width=30.25
Clear Opening Height=12.783
Clear Opening Area=2.685318
SKU=260803
Vendor Name=S/O SILVER LINE BLDG PRD
Vendor Number=60660514
Customer Service=(888)888-7020
Catalog Version Date=11/18/2016
www.HomeDepot.com Page 7 of 11 Printed By: JAMES Date Printed: 1/17/2017 2:14 PM
900-1 70 Series Impact Patio Doors 2 Panel-5802IMPACT - $1,404. 2 $2,809.10
71.625 x 80 $1,193.73 $2,387.46
Installation Zip Code=34951
U.S. ENERGY STAR®Climate Zone=Southern Save$421.64(15%) until 1/18/2017
ENERGY STAR Required=No *S/0 SILVER LINE BLDG PRD-273308 Promotion
Standard Width=RO:72 1/8" UNIT:715/8" until 1/18/2017
Standard Height=R0:801/2" UNIT:80"
Frame Width=715/8
Frame Height=80
Unit Code=60x68 _ _
Venting/Handing=Left-Stationary _._
Exterior Color=White I
Interior Finish Color=White
Performance Grade(PG) Rating=PG50
Unit 1: Patio Door Assembly=Factory Assembled
Unit 1 Left Slab Left Glass,1 Right Slab Right Glass:Glass
Construction Type=Dual Pane s
Unit 1 Left Slab Left Glass, 1 Right Slab Right Glass:Glass
Option=Low-E Sun Argon
Unit 1 Left Slab Left Glass, 1 Right Slab Right Glass: High I
Altitude Breather Tubes=No
Unit 1 Left Slab Left Glass, 1 Right Slab Right Glass: Glass
Strength=Tempered Impact Resistant
Unit 1 Left Slab Left Glass,1 Right Slab Right Glass: Glass Y
Tint=No Tint
Unit 1 Left Slab Left Glass,1 Right Slab Right Glass: 71S'8 --
Specialty Glass=None RO-72 L3
Unit 1 Left Slab Left Glass,1 Right Slab Right Glass:Gas
Fill=Argon
None
Hardware=Stainless Steel
Insect Screen Type=Full Screen
Insect Screen Material=Fiberglass
Re-Order Item=No
Room Location=Kitchen
Unit U-Factor=0.27
Unit Solar Heat Gain Coefficient(SHGC)=0.22
U.S.ENERGY STAR Certified=Yes
SKU=273308
Vendor Name=S/0 SILVER LINE BLDG PRD
Vendor Number=60660514
Customer Service=(888)888-7020
Catalog Version Date=11/18/2016
Pre-Tax Price: $19,574).67
Promotional Price: $9,495.24
**AII prices are subject to change
**Customer is responsible for verifying product selections.The Home Depot will not accept returns for the above products
**AII graphics viewed from the exterior
www.HomeDepot.com Page 8 of 11 Printed By: JAMES Date Printed: 1/17/2017 2:14 PM
Rpsmil
IAC I. IMITFD 10 Y F A R
Florida'sBest® WARRANTY
WINDOW&DOOR