Loading...
HomeMy WebLinkAboutProduct Approval (2) R,ECFI',_D !AN 1 -.i ? 1 SilverLine ff`i 4" byAndersen _ J=a �N m WINDOWS • DOORS Z1 .111�11a N•• O SERIES 3600 MODEL 3601/3611 Kto 9 m`W E ❑a p o a 50.0"MAx.O.A. \v a N a m EXTRUDEDVINYL FIN TOFIN WIDTH ? oZ TILT DOUBLE HUNG WINDOW f 46.�1 •a•A ^1 �W FRAME WIDTH o LL A w/ NAILING FIN 3 fn Z "IMPACT' ' 3 �_ v W ^ J �� GENERAL NOTES = w w This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building m Z5 Code(FBC)structural requirements including the"High Velocity Hurricane Zone"(HVHZ). z LL o o w q o a 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material o shall be beyond wall dressing or stucco. } D b a] 3. When used in the"HVHT'this product complies with section 1626 of the Florida Building Code and does X not require an impact resistant covering. / m Z 4. When used in areas outside of the"HVHT'requiring wind bome debris protection this product complies o with Section 1609.1.2 of the FBC and does not require an impact resistant covering.This product meets z missile level"D"and includes Wind Zone 4 as defined in ASTM El 996 and Section 1609.1.2.2 of the FBC. LL - W o � I 5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck emasonry construction. a 6. Site conditions that deviate from the details of this drawing require further engineering analysis by a a licensed engineer or registered architect. = N 7. This product meets water infiltration requirements for'TiVHZ". t �2 w Z 0 o - n TABLE OF CONTENTS °S:OVERA(1 - -MAX. - - - MAX - '=DESIGN PRESSURE(PSI), -z i SHEET DESCRIPTION FIN FRAME. D.LO.'. GLASS a 1 Typical elevations,design pressures&general notes DIMENSION- DIMENSION DIMENSION TYPE POSITIVE, NEfATIVE- DATE:10/24/13 i 2 Horizontal and vertical cross sections +50.0 50.0 SCALE: N.T.S. 9 50.0"X 76.0" 46.0"X 72.0" 40.06"X 32.19" G 1,G2 3 Horizontal and vertical cross sections DWG.BY: JK m A. 4 Buck and frame anchoring CHK.aY: LFS 3 5 Components DRAWING NO.: 6 Bill of materials&glazing details FL-14996.7 4 0 SHEET_L DF 6 N V f. K R:\Clients Silverline Buildina Products-P Florida Product A royals FL-14996 Double Hun C-Drawin s FL 14996 2014 FL-14996.10-.14.dw 14-2 a v v v a v v 0 V Gl D pg p W � N 3 N N IA o X00 1 O IA IA N A a 0 � n _ V O O —z Z �� O R CD m O O� a° Wa a ° o ID ° IIIIIIIINIMMMM o.$ ° 0. ,4 Oa 4< 4° 3 w m < a x x T O � m ° � a rn 0) U� N r0 N N Cn D cn oO� a. < O^ U\ 70 DO o N O n O gn T D W V [�) DD rn 10 ti O N m 4 Z ° o _ Q m v 0 D- 1-1/4"MIN. EMB.(TYPJ 1F`Sc 'tf T PRODUCT: Doeuments Pmpared By:� Lyndon F. Schmidt '�j�•• ('' n t DOUBLE HUNG WINDOW P.E. No. 43409 1,17111 SS` o '7111 1DIYAI. �� IN a o Z� m 111111111111 , N PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. IT in 1 3 18 15 UPDATE TO 5TH ED. (2014) FBC X J V�P.O. Box 230, Valrtco, FL 33595 ° w NO DATE BY HORIZONTAL & VERTICAL CROSS SECTIONS phone No.: 813.859.9197 REVISIONS FBPE C.A. No. 9813 0 2013 R.W.BUILDING CONSULTANTS INC. R:\Clients\Silverline Buildinq Products- Florida Product A rovals\FL-14996 Double Hun C-Drawin s\FL 14996 2014\FL-14996.10-.14.dw,14-3 Q o oma° O V A W � � A N 5O o A 2n A o � n O � V Z O O 7 N ry Z 0 0 0 m 0) ao wo a a(D o CL r_ a �Do o- a o = 0 3 N O P- 0 0 ` rn N a DO L4 r_ � N W A> to ao ole 0� aO Q n� n 0 n LT), Ilu i- on DO O7 0. �O y oo D N to W 0 D W Z N 10 m m Z 38 Is,CH41,0'7�7i j � No.43409 PRODUCT: Document. Prepared By:'i F x P n L ndon F. Schmidt ��j�'• r o DOUBLE HUNG WINDOW P E. No. 43408 \ m ��nnnnar o " y .Np PART OR ASSEMBLY: �K BUILDING in\ 1 3 18 15 UPDATE TO 5TH ED. (2014) FSC JK J l� P.O. Box CONSULTANTS, INC. 230, Valrico, FL 33595 O1 j, x W NO DATE BY HORIZONTALSECTIONSCAL CROSS Phone No.: 81 3.659.9197 REVISIONS I FBPE C.A. No. 9813 2013 R.W.BUILDING CDNSU-NTS INC. i a �O 'So � 2X FRAMING TO BE DESIGNED BY THE ENGINEER OR ARCHFIECT Z �l�` m OFR BASED ON WIND LOADS w•' _ AND THE CLADDING BEING USED. ��� ,•�,C, o m (TYP,.O.C. -+{ 7, S'MAX.O.C. '� ��trlt*F'tt���Y~` a n 0 i ' -- (TYP-) ///))) TYP. (fYP,.) t $ a x zo- •V�. 4 v U o 2„ . Z m U TYP. a N j d r a c d C `0: Y K TYP. �d D TYP. 2X BUCK j J TYP. t d O— d U 2X BUCK 0: O o o Z U MEETING '- RAIL F. 3 LU X w MASONRY d MASONRYF --1 4 OPENING OPENING T F (1)THRU FRAME T U ti' 'el MIDSPAN OF , a EACHJAMB tij THRU FRAME of m ®MIDSPAN OF °1 FRAME EACH JAMB a I m FRAME }} m a 4 N � v Z BUCKANCHORING FRAME ANCHORING FRAMEANCHORING w 2X buck construction r Stud construction CQNCREfEANCHORNOTES: m i 1.Concrete anchor locations at the comers may be adjusted to maintain the min. 100 edge distance to mortarjoints. < 2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to r; maintain the min,edge distance to martar joints,additional concrete anchors o may be required to ensure the"MAX,ON CENTER"dimension are not exceeded. m m 3.Concrete anchor table: -LU z a mQ - o � ANCHOR ANCHOR MIN MIN.CLEARANCE: MIN:CLEARANCE � z TYPE SIZE EMBEDMENT ., TO MASONRY TOADJACENT EDGE' ANCHOR z aITW ° V PC ouE:16124113 z $ TAPCON� 1/4' T-i/4" 2" q" o i sc&E: N.T.S. o ELCO 5 ULTRACON® 1/4" 1.1/4" 1" 4" owc.Br: JK m m 3 WOOD SCREW INSTALLATION NATES: CHK.SY: LFSoRaw � I.Maintain a minimum SIF edge distance,I"end distance,&I"D.C.spacing of lHc ao.: m wood screws to prevent the splitting of wood. FL-14996.14 a SHEET 4 OF 6 r R-.\Clients\Silverline Building Products-%Florida Product Approvals\FL-14996 Double Hung\C-Drawings\FL 14996(2014)\FL-14996.10-.14.dwg,14-5 2.59" F+1.557' 2 y ? 2 Ln m c ooL 7' �O y 0.0 0.73' m> 2 N z 0 V �{ 1.435' r ? T A T in 2 y H 2.05" 70 A T TIN 0.51" n1.545'- r.01 t T171I o F56P] 0.05' A a� so 90 0.84" 0 s 11+7 y Z 1.557'� co Gl D N H E3 t9 A " --►{ 1.435" O I T} IJV � I n y V D m 0 ��•��v•�vc�ivaF••.T .� / No.43408 ' D PRODUCT: DooumentB PrePerod ey:�� t" Lyndon F. Schmidt ,,, �(.� I� \ DOUBLE HUNG WINDOW P.E. No. 43409 to o ''7is�QIVALI o - y PART OR ASSEMBLY: �K BUILDING CONSULTANTS, INC. 1 —3/-11371-5 UPDATE 70 5TH ED. (2014) FBC JK COMPONENTS J l� P.O. Box 230, Valrico, FL 33595 y C, NO DATE BY Phone No.: 813.859.9197 REVISIONS FBPE CA No. 9813 '02013 R.W.8UILDING C-6—A—B INC. BILL OF MATERIALS . *It% ITEM B DESCRIPTION MATERIAL � A, .-a-A 2X FRAMING SG>=0.42 WOOD =at o 'j'B 2X BUCK SG>=0.42 WOODD 114"X 2-3/4"PFH ELCO OR TTW CONCRETE SCREW STEEL Ni 7 ZMASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI c E301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE yF #10 X 2"FH WOOD SCREW STEEL 1/7'GLASS 7/8"OVERALL GLASS THK. i1 ' * ��% m M m iG 1/4"MAX SHIM SPACE BITE ILII I0 N '. J #8 X 2"PPH SMS(1-3/4-MIN.EMBEDMENT) STEEL 20 40 1/8"ANNEALED GLASS c� p i o z L) K #S X 1-1/7'PPH SMS(1-314-MIN.EMBEDMENT) STEEL \ N a v v 9 0 o a 1 EXTRUDED PVC MAIN FRAME HEAD/JAMB#52-3001' PVC V m 'G.t m 2 EXTRUDED PVC MAIN FRAME SILL#52-3003` PVC 0.090"DuPONT BUTACITE® sa 3 HEAD ADAPTER#50 9522(6063 T6) ALUMINUM PVB INTERLAYER o Z 4 EXTRUDED PVC GLAZING BEAD#1227* PVC 1/8"ANNEALED GLASS �w 5 EXTRUDED PVC UPPER LIFT RAIL#52-8506` PVC AIR SPACE 6 EXTRUDED PVC UPPER SASH BOTTOM RAIL#52-8507PVC 7 EXTRUDED PVC UPPER SASH STILES#52-8504` PVC Q } o J 8 EXTRUDED PVC LOWER SASH TOP RAIL#52-8508' PVC = 9 EXTRUDED PVC LOWER LIFT RAIL#52-8506' PVC 37 10 EXTRUDED PVC LOWER SASH STILES#52-8505` PVC 4 1/8"ANNEALED GLASS 12 UPPER SASH KEEPER STEEL J � GT GLAZING DETAIL Lu 13 LOWER SASHLOCK STEEL w 14 #8-32 X 1/2"PPH MS STEEL 16 PILE WEATHERSTRIP W/FIN " o 0 m 18 BULB SEAL Q-LON 0 19 UPPER SASH LATCH PVC 1/Z'GLASS 7/8"OVERALL GLASS THK. a a BITE20 GLAZING SILICONE(DOW 995) SILICONE 40 GO 0 21 UPPER SASH TILT LATCH(NOT SHOWN) PLASTIC 20 1/8 ANNEALED GLASS 22 UPPER SASH PIVOT BAR(NOT SHOWN) STEEL 28 #8 X 1"PFHSCREW STEEL 0.090"DuPONT BUTACITE 29 #6 X 1"PFH SCREW ZINC PLATED STEEL PVB INTERLAYER a 31 SASH LOCK ASSY(DIE CAST ZINC ALUMINUM) 1/8 ANNEALED GLASS N N 32 SASH LOCK KEEPER(ZINC DIE CAST) z 34 KEEPER RAIL&STILE REINFORCEMENT#50-9523 ALUMINUM AIR SPACE w s -il35 LIFT RAIL REINFORCEMENT#50-9530 ALUMINUM L - 36 LOCK RAIL REINFORCEMENT#50-9529 ALUMINUM Q R o 37 GLAZING SPACER(INTERCEPT) STEEL < 43 GLAZING SILICONE(TREMCO S7000) SIUCONE o 43 GLAZING SPACER SUPERSPACER) PVC 4 43 1/ 40 GLASS i _ G2 GLAZING DETAIL �� a I 'a - , THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BEn PRODUCED BY EXTRUDERS LICENSEES IN "AAMA CERTIFICATION PROGRAMS FOR RIGID n z PVC EXTRUSIONS". DAm 10/24/13 i SCALE: N.T.S. ° CHK.BY. LFS 3 DRAWING NO.: FL-14996.14 m m SHEET_L OF 6 N V K R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Product Evaluation Report // I /// Iat&:, APHIZ 2015, Product Sub Category Manufacturer Product Name Category Silverline Building Products Series 3600 Model 360113611 Windows Double Hung 1 Silverline Drive Extruded Vinyl North Brunswick,NJ 08902 Tilt Double Hung Window w1 Nailing Fin Phone-732.435.1000 "Impact' Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc.and Lyndon F.Schmidt, P.E.(System ID# 1998)for Silverline Building Products based on Rule Chapter No.61 G20-3,Method 1 D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code(FBC)structural requirements includinq the"High Velocitv Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the"HVHZ"this product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. When used in areas outside of the"HVHZ"requiring wind borne debris protection this product complies with Section 1609.1.2 of the 2010 FBC and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E1996. 5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of drawing FL-14996.14 require further engineering analysis by a licensed engineer or registered architect. 7. This product meets the water infiltration requirements for"HVHZ". 8. See drawing FL-14996.14 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by ATI C7606.03-109-18 TAS 201,202&203-94 Architectural Testing, Inc. Michael D.Stremmel, P.E. Materials PVC Extrusions ETC 97-26440910 ASTM D635-96,D1929-96, D2843-93 ETC,Laboratories J.L.Doldan, P.E. D638-96 and G26-95 2. Miami-Dade NOA Materials Testing 13-0129.27 PVB Interlayer by DuPont 3. Drawing No. Prepared by Signed&Sealed by No.FL-14996.14 RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt,P.E. 4. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) Lyndon F.Schmidt,P.E. ASTM E1300 Glass Load Lyndon F. Schmidt,P.E. "=; s 5. Quality Assurance X 's Certificate of Participation issued by Window&Door Manufacturers Association,certifying that Silverline Building Products Corporation is manufacturing products within a quality assurance program that complies. with ISOIIEC 17020 and Guise 53. s r' '1 Lyndon F.Schmidt,P.E. FL PE No.43409 412812015 Sheet 1 of 1 NOTICE OF PRODUCT CERTIFICATION CERTIFICATION NO: NI011202-R1 DATE: 07/25/2012 m x CERTIFICATION PROGRAM: Structural sc ,� COMPANY: T.M. Window CODE: T-829-1 -'QE,►;E.,T` -. REVISION DATE: 02/27/2015 FlEO pno To verify that the"Notice of Product Certification"is valid,please visit www.NAMlCerti I ication.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION T. M. Windows,LLC Series "DH93WW Unequal Glass" 1543 N.Powerline Road PVC Double Hung Window Pompano Beach, FL 33069 Configuration:X/X Glazing: Insulating Glass(Annealed) Frame: W-1372mm(54") H-2134mm(84") Sash: W-1289mm(50.75") H-1059mm(41.69") SPECIFICATION PRODUCT RATING AAMA/WDMA/CSA 101/I.S.2/A440-08 Class LC-PG70 1372 x 2134 (54 x 84)-H Design Pressure: 3360 Pa (70 psf) Water Penetration Resistance Test Pressure:580 Pa(12.12 pso Product Tested By: Architectural Testing, Inc. Report No: A8440.03-501-47/A8440.02-501-47 Expiration Date: June 30,2019 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel: (804)684-5124 Fax: (804)684-5122 NOTICE OF PRODUCT CERTIFICATION C IF��q ' CERTIFICATION NO: N1011210-R1 DATE: 07/25/2012 CERTIFICATION PROGRAM: Structural COMPANY: T.M. Window CODE: T-829-1 ' ►�,eo P�fla� REVISION DATE: 02/27/2015 To verify that the"Notice of Product Certification"is valid,please visit www.NANIICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION T. M. Windows,LLC Series "DH93WW/Sloped" 1543 N. Powerline Road PVC Double Hung Window Pompano Beach, FL 33069 Configuration:X/X Glazing: 1/8"Annealed Glass/Laminate- 1/8"Annealed Glass/0.090"DuPont Butacite PVB/ 1/8"Annealed Glass Frame: W-1372mm(54") H-2134mm(84") Sash: W-1286mm(50.63") H-1057mm(41.63") SPECIFICATION PRODUCT RATING ASTM E1886-05/E1996-05 Design Pressure: +70/-70 psf Wind Zone 3-Missile Level D Product Tested By: Architectural Testing, Inc. Report No: B0829.01-501-47 Expiration Date: June 30,2019 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel: (804)684-5124 Fax: (804)684-5122 L. Roberto Lomas P.E. Engineering Evaluation Report 233 W.Main St Danville,VA 24541 Report No.: 512283A 434-688-0609 rlloiiias@lrloiTiaspe.com Irlomaspe.com Manufacturer: TM Windows L.L.C. 1543 North Powerline Rd. Pompano Beach, FL 33021 Product Line: Series"DH93WW Unequal Glass"PVC Double Hung Window Reinforced-LMI Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a).The product listed herein complies with requirements of the Florida Building Code Supporting Technical Documentation: 1. Approval document: drawing number 08-01618 Revision B, prepared,signed and sealed by Luis Roberto Lomas P.E. 2. Report No.:A8440.03-501-47 signed by Lynn George Architectural Testing Laboratories, Springdale, PA AAMA/WDMA/CSA 101/i.S.2/A440-08 Design pressure: ±70.Opsf Water penetration resistance 12.2psf 3. Report No.: 80829.01-501-44 signed by Lynn George Architectural Testing Laboratories, Springdale, PA ASTM E1886-05 and ASTM E1996-05 ASTM E1886/E1996 Large Missile Impact, Level D,Wind Zone 3 ASTM E1886/E1996 Cyclic Load Test, ±70.Opsf design pressure 4. Anchor calculations, report number 512283-1, prepared,signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: • Maximum design pressure: ±70.Opsf • Maximum unit size: 54"x 84" • Units must be glazed per ASTM El 300-04, see installation instructions for glass details. • This product is not rated to be used in the HVHZ. • This product is impact resistant and does not require impact protection in wind borne debris regions, up to wind zone 3. • Frame material to be rigid PVC. Installation: Units must be installed in accordance with approval document, 08-01618 Revision B Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the product(s)for which this report is being issued.Also, I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s). \�� i CP ;* 0 51 TATE OF ;t� �� • . . . - V, /iss/4NA� E�G� /rnlll 1 of 1 Luis R. Lomas, P.E. FL No.:62514 02/27/2015 R W R W Building Consultants, Inc. B Consulting and Engineering Services lbr the Building Industry C P.O.Box 23U Valrico,FL 33595 Phone 813.659.9197 Florida Board orProlicssional Engineers Certificate orAnihorizition No.9813 Product / Report Report IFL-14996.14 Aprill Product Sub Category Manufacturer Product Name Category Silverline Building Products Series 3600 Model 360113611 Windows Double Hung 1 Silverline Drive Extruded Vinyl North Brunswick,NJ 08902 Tilt Double Hung Window w/Nailing Fin Phone-732.435.1000 "Impact" Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc.and Lyndon F.Schmidt, P.E.(System ID# 1998)for Silverline Building Products based on Rule Chapter No.61G20-3,Method 1D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt, P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code(FBC)structural requirements including the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the"HVHZ"this product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. When used in areas outside of the"HVHZ"requiring wind borne debris protection this product complies with Section 1609.1.2 of the 2010 FBC and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E1996. 5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of drawing FL-14996.14 require further engineering analysis by a licensed engineer or registered architect. 7. This product meets the water infiltration requirements for"HVHZ". 8. See drawing FL-14996.14 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by ATI C7606.03-109-18 TAS 201,202&203-94 Architectural Testing, Inc. Michael D.Stremmel,P.E. Materials PVC Extrusions ETC 97-26440910 ASTM D635-96,D1929-96,D2843-93 ETC,Laboratories J.L. Doldan, P.E. D638-96 and G26-95 2. Miami-Dade NOA Materials Testing 13-0129.27 PVB Interlayer by DuPont 3. Drawing No. Prepared by Signed&Sealed by No.FL-14996.14 RW Building Consultants, Inc.(CA 49813) Lyndon F.Schmidt, P.E. 4. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt, P.E. ASTM E1300 Glass Load Lyndon F.Schmidt,P.E. 5. Quality Assurance Certificate of Participation issued by Window&Door Manufacturers Association,certifying that Silverline Building Products Corporation is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guise 53. Lyndon F.Schmidt,P.E. FL PE No.43409 4/28/2015 Sheet 1 of 1 The Home Depot Special Order Quote �., Customer Agreement#: H0213-26255 , f Printed Date:1/17/2017` Customer Information Store Information Name LORALYNNE SCHNEIDER Store Number 0213 Address 7605 PENSACOLA RD FORT PIERCE FL Address 1885 58TH AVE PA41PIERCE, FL 34951 VERO BEACH, FL 32966 Primary Phone 443-825-9155 Associate JAMES Secondary Phone 443-825-9155 ffi�6J�l � ,} (Q�g��je _ �.fL•di..kI4. '�_.._..__._ _nE 100-1 Series 9650 Double Hung 36.125 x 60.5 - $716.07 4 $2,864.28 Frame Width=36.125 Frame Height=60.5 Sash Split=Even SKU=1000030331 Vendor Name=TM Window Vendor Number=60074855 Manufacturer=TM Window Customer Service=1-954-781-4430 Catalog Version Date=3/4/16 Lead Time=28 Days Room Location=Custom Custom Location=sewing room Code Version=Code Version Florida Building Code=15804.1 Screen=Full Screen Exterior Finish=White Interior Finish=White Maximum Design Pressure=DP+/-70 Glass Thickness=1" Glass Strength=Annealed Glass Interlayer=PVB Product Approval Glass Code=VP DH Meets Energy Star Requirements=Yes Meet Turtle Code=No Low-E=High Performance Low-E(Cardinal 366) ti----- 361.'8 -i Argon Gas=Yes Glass Tint=Clear Frame Type=Box Frame with 5/8"Snap-on Flange Snap-On Interior Frame Accessory=Frame Plug Meets HVHZ Requirements=No Meet 2014 FBC Energy Requirements=Yes Climate Zone=Zone 1&2 Glass Type=Insulated Impact Lock Type=Sweep Lock Overall Frame Width=36.125 Overall Frame Height=60.5 Overall TipToTip Width=37.125 _ Overall TipToTip Height=61.5 e,5 &d) ZlrrA) www.HomeDepot.com Page 1 of 11 Printed By: JAMES /17/2017 2:14 PM P (� n 200-1 Bay Mull Bar Accessory Other - $225.73 2 $451.46 SKU=1000030342 Vendor Name=TM Window Vendor Number=60074855 Manufacturer=TM Window Customer Service=1-954-781-4430 Catalog Version Date=3/4/16 Lead Time=10 Days Include Mull Clips=Yes Mull Clip=Bay Mull Clip-Qty:2 Mull Series=45 Degree Bay Mull Mull Width&Height=3.163"x 3.432" Mull Wall Thickness=1/4" Engineering Document Included=Yes Mull Bar Length=60.5 Two Tone Color Finish=No Exterior Finish=White Interior Finish=White Finish Type=Standard Paint Finish Warranty=1 Year Coastal/3 Year Inland Warranty 300-1 Aluminum Mull Bar Accessory Other - $87.84 1 $87.84 SKU=1000030342 Vendor Name=TM Window Vendor Number=60074855 Manufacturer=TM Window Customer Service=1-954-781-4430 Catalog Version Date=3/4/16 Lead Time=10 Days Code Version=Code Version Florida Building Code=13188.2 Meets HVHZ Requirements=Yes Include Mull Clips=Yes Mull Clip=1"x 4" Mull Clip-Qty:2 Mull Clip Screw Pack=For Non-Casement Windows Mull Series=Rectangular w/Exterior Vinyl Cap Mull Width&Height=1"x 4" Mull Wall Thickness=1/8" Mull Bar Length=60.5 Two Tone Color Finish=No Exterior Finish=White Interior Finish=White Finish Type=Standard Paint. Finish Warranty=1 Year Coastal/3 Year Inland Warranty www.HomeDepot.com Page 2 of 11 Printed By: JAMES Date Printed: 1/17/2017 2:14 PM l 'In° 9;�(a o:`�?. i _ Rf�.4 Ati �l 7j �( lr'tn j..... __ t 400-1 70 Series NFJ Impact Double-Hung-36011MPACT - rc 2 $ 36.125 x 60.5 $555.30 $1,110.60 Installation Zip Code=34951 U.S.ENERGY STAR®Climate Zone=Southern Save$196.00(15%) until 1/18/2017 ENERGY STAR Required=No *S/0 SILVER LINE BLDG PRD-260803 Promotion Standard Width=Custom until 1/18/2017 Standard Height=Custom Frame Width=36 1/8 Frame Height=601/2 Exterior Color=White Interior Finish Color=White Performance Grade(PG) Rating=PG50 Glass Construction Type=Dual Pane Glass Option=Low-E Sun Argon High Altitude Breather Tubes=No Glass Strength=Impact Resistant _ Glass Tint=No Tint `D Specialty Glass=None c Gas Fill=Argon None Number of Sash Locks=Double Lock Type=Standard Insect Screen Type=Full Screen Insect Screen Material=Fiberglass Foam=No J-Channel Filler=Yes Extension Jamb Type=None Re-Order Item=No i 36 118 Room Location=Custom Location Custom(Enter Room Name)=sewing room ►--- RO-36 518 -- --i Unit U-Factor=0.31 Unit Solar Heat Gain Coefficient(SHGC)=0.21 U.S.ENERGY STAR Certified=Yes Florida Product Approval Number(FL#)=14996 High Velocity Hurricane Zone(HVHZ)=Yes SKU=260803 Vendor Name=S/0 SILVER LINE BLDG PRD Vendor Number=60660514 Customer Service=(888)888-7020 Catalog Version Date=11/18/2016 www.HomeDepot.com Page 3 of 11 Printed By: JAMES Date Printed: 1/17/2017 2:14 PM 500-1 70 Series NFJ Impact Double-Hung-36011MPACT - 5 2 $1,152.10 26 x 60.5 $489.64 $979.28 Installation Zip Code=34951 U.S.ENERGY STAR®Climate Zone=Southern Save$172.82(15%) until 1/18/2017 ENERGY STAR Required=No *S/0 SILVER LINE BLDG PRD-260803 Promotion Standard Width=Custom until 1/18/2017 Standard Height=Custom Frame Width=26 Frame Height=601/2 Exterior Color=White Interior Finish Color=White Performance Grade(PG) Rating=PG50 Glass Construction Type=Dual Pane _ Glass Option=Low-E Sun Argon High Altitude Breather Tubes=No Glass Strength=Impact Resistant Glass Tint=No Tint `D Iz! Specialty Glass=None c Gas Fill=Argon None Number of Sash Locks=Double Lock Type=Standard Insect Screen Type=Full Screen Insect Screen Material=Fiberglass Foam=No J-Channel Filler=Yes Extension Jamb Type=None Re-Order Item=No �- 25 -i Room Location=Living Room Unit U-Factor=0.31 t- RO-26 112 i Unit Solar Heat Gain Coefficient(SHGC)=0.21 U.S. ENERGY STAR Certified=Yes Florida Product Approval Number(FL#)=14996 High Velocity Hurricane Zone(HVHZ)=Yes SKU=260803 Vendor Name=S/0 SILVER LINE BLDG PRD Vendor Number=60660514 Customer Service=(888)888-7020 Catalog Version Date=11/18/2016 www.HomeDepot.com Page 4 of 11 Printed By: JAMES Date Printed: 1/17/2017 2:14 PM " " °� �o o An)){ h�i r ry il -- 600-1 70 Series NFJ Impact Double-Hung-36011MPACT - r` 23 ?�8 25.5 x 60.5 $485.69 $971.38 Installation Zip Code=34951 U.S.ENERGY STAR®Climate Zone=Southern Save$171.40(15%)until 1/18/2017 ENERGY STAR Required=No *S/0 SILVER LINE BLDG PRD-260803 Promotion Standard Width=Custom until 1/18/2017 Standard Height=Custom Frame Width=25 1/2 Frame Height=60 1/2 Exterior Color=White Interior Finish Color=White Performance Grade(PG) Rating=PG50 Glass Construction Type=Dual Pane Glass Option=Low-E Sun Argon \,r7 High Altitude Breather Tubes=No Glass Strength=Impact Resistant Glass Tint=No Tint Specialty Glass=None Gas Fill=Argon None Number of Sash Locks=Double Lock Type=Standard Insect Screen Type=Full Screen Insect Screen Material=Fiberglass Foam=No J-Channel Filler=Yes Extension Jamb Type=None Re-Order Item=No 25 112Room Location=Living Room ~ � Unit U-Factor=0.31 t RO-26 ----s Unit Solar Heat Gain Coefficient(SHGC)=0.21 U.S. ENERGY STAR Certified=Yes Florida Product Approval Number(FL#)=14996 High Velocity Hurricane Zone(HVHZ)=Yes SKU=260803 Vendor Name=S/0 SILVER LINE BLDG PRD Vendor Number=60660514 Customer Service=(888)888-7020 Catalog Version Date=11/18/2016 www.HomeDepot.com Page 5 of 11 Printed By: JAMES Date Printed: 1/17/2017 2:14 PM taLCx3_ �ra= 700-1 70 Series NFJ Impact Single-Hung-29011MPACT - Y $366.48a1 &S 24.5 x 36.75 $311.50 $311.50 Installation Zip Code=34951 U.S. ENERGY STAR®Climate Zone=Southern Save$54.98(15%)until 1/18/2017 ENERGY STAR Required=No *S/0 SILVER LINE BLDG PRD-260803 Promotion Standard Width=Custom until 1/18/2017 Standard Height=Custom Frame Width=24 1/2 Frame Height=36 3/4 Exterior Color=White Interior Finish Color=White Performance Grade(PG) Rating=PG50 Glass Construction Type=Dual Pane Glass Option=Low-E Sun Argon High Altitude Breather Tubes=No Glass Strength=Impact Resistant Glass Tint=No Tint r Specialty Glass=Obscure cry Gas Fill=Argon C; None Hardware Color/Finish=White Number of Sash Locks=Single Lock Type=Standard Window Opening Control Device=Factory Applied Window Opening Control Device Color=White Insect Screen Type=Half Screen Insect Screen Material=Fiberglass 24 1/2 Foam=No i Raj -25 Drywall Return=No J-Channel Filler=Yes Extension Jamb Type=None Re-Order Item=No Room Location=Bathroom#2 Unit U-Factor=0.33 Unit Solar Heat Gain Coefficient(SHGC)=0.23 U.S. ENERGY STAR Certified=Yes Florida Product Approval Number(FL#)=14911 High Velocity Hurricane Zone(HVHZ)=Yes Clear Opening Width=19.5 Clear Opening Height=12.908 Clear Opening Area=1.747958 SKU=260803 Vendor Name=S/0 SILVER LINE BLDG PRD Vendor Number=60660514 Customer Service=(888)888-7020 Catalog Version Date=11/18/2016 www.HomeDepot.com Page 6 of 11 Printed By: JAMES Date Printed: 1/17/2017 2:14 PM 800-1 70 Series NFJ Impact Single-Hung-29011MPACT $389.9B 1 $389.93 35.25 x 36.5 $331.44 $331.44 Installation Zip Code=34951 U.S.ENERGY STAR®Climate Zone=Southern Save$58.49(15%) until 1/18/2017 ENERGY STAR Required=No *S/O SILVER LINE BLDG PRD-260803 Promotion Standard Width=Custom until 1/18/2017 Standard Height=Custom Frame Width=35 1/4 Frame Height=36 1/2 Exterior Color=White Interior Finish Color=White Performance Grade(PG) Rating=PG50 Glass Construction Type=Dual Pane Glass Option=Low-E Sun Argon High Altitude Breather Tubes=No Glass Strength=Impact Resistant Glass Tint=No Tint Specialty Glass=None o CD Gas Fill=Argon m None Hardware Color/Finish=White Number of Sash Locks=Double Lock Type=Standard Window Opening Control Device=No Insect Screen Type=Half Screen 35 V4 Insect Screen Material=Fiberglass f-- RO-35 314 Foam=No Drywall Return=No J-Channel Filler=Yes Extension Jamb Type=None Re-Order Item=No Room Location=Garage Unit U-Factor=0.33 Unit Solar Heat Gain Coefficient(SHGC)=0.23 U.S.ENERGY STAR Certified=Yes Florida Product Approval Number(FL#)=14911 High Velocity Hurricane Zone(HVHZ)=Yes Clear Opening Width=30.25 Clear Opening Height=12.783 Clear Opening Area=2.685318 SKU=260803 Vendor Name=S/O SILVER LINE BLDG PRD Vendor Number=60660514 Customer Service=(888)888-7020 Catalog Version Date=11/18/2016 www.HomeDepot.com Page 7 of 11 Printed By: JAMES Date Printed: 1/17/2017 2:14 PM 900-1 70 Series Impact Patio Doors 2 Panel-5802IMPACT - $1,404. 2 $2,809.10 71.625 x 80 $1,193.73 $2,387.46 Installation Zip Code=34951 U.S. ENERGY STAR®Climate Zone=Southern Save$421.64(15%) until 1/18/2017 ENERGY STAR Required=No *S/0 SILVER LINE BLDG PRD-273308 Promotion Standard Width=RO:72 1/8" UNIT:715/8" until 1/18/2017 Standard Height=R0:801/2" UNIT:80" Frame Width=715/8 Frame Height=80 Unit Code=60x68 _ _ Venting/Handing=Left-Stationary _._ Exterior Color=White I Interior Finish Color=White Performance Grade(PG) Rating=PG50 Unit 1: Patio Door Assembly=Factory Assembled Unit 1 Left Slab Left Glass,1 Right Slab Right Glass:Glass Construction Type=Dual Pane s Unit 1 Left Slab Left Glass, 1 Right Slab Right Glass:Glass Option=Low-E Sun Argon Unit 1 Left Slab Left Glass, 1 Right Slab Right Glass: High I Altitude Breather Tubes=No Unit 1 Left Slab Left Glass, 1 Right Slab Right Glass: Glass Strength=Tempered Impact Resistant Unit 1 Left Slab Left Glass,1 Right Slab Right Glass: Glass Y Tint=No Tint Unit 1 Left Slab Left Glass,1 Right Slab Right Glass: 71S'8 -- Specialty Glass=None RO-72 L3 Unit 1 Left Slab Left Glass,1 Right Slab Right Glass:Gas Fill=Argon None Hardware=Stainless Steel Insect Screen Type=Full Screen Insect Screen Material=Fiberglass Re-Order Item=No Room Location=Kitchen Unit U-Factor=0.27 Unit Solar Heat Gain Coefficient(SHGC)=0.22 U.S.ENERGY STAR Certified=Yes SKU=273308 Vendor Name=S/0 SILVER LINE BLDG PRD Vendor Number=60660514 Customer Service=(888)888-7020 Catalog Version Date=11/18/2016 Pre-Tax Price: $19,574).67 Promotional Price: $9,495.24 **AII prices are subject to change **Customer is responsible for verifying product selections.The Home Depot will not accept returns for the above products **AII graphics viewed from the exterior www.HomeDepot.com Page 8 of 11 Printed By: JAMES Date Printed: 1/17/2017 2:14 PM Rpsmil IAC I. IMITFD 10 Y F A R Florida'sBest® WARRANTY WINDOW&DOOR