FL# FL10124-R15
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑ I
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany,NJ 07054
(973)872-4421
lindareith@trinityerd.com
Authorized Signature Beth McSorley
lindareith@trinityerd.com
Technical Representative Beth McSorley(current)
Address/Phone/Email 1 Campus Drive
Parsippany,NJ 07054
(973)872-4421
bmcsorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑� Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 11/21/2016
Validated By John W.Knezevich,PE
® Validation Checklist-Hardcopy Received
Certificate of Independence FL10124 R15 COI 2015 01 COT Nleminen.Ddf
Referenced Standard and Year(of Standard) Standard year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
TAS 107 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 03/31/2015
Date Validated 04/08/2015
Date Pending FBC Approval 04/12/2015
Date Approved 06/23/2015
Summary of Products
FL# IlModel,Number or Name Description
10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,laminated,5-tab and hip/ridge asphalt
shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10124 R15 iI 2015 03 FINAL ER GAF Asphalt Shingles FL10124-
Approved for use outside HVHZ:Yes
Impact Resistant:N/A Verified By:Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section 5. Evaluation Reports
FL10124 R15 AE 2015 03 FINAL ER GAF Asphalt Shingles FL10124-
15 d
Created by Independent Third Party:Yes
WE WIN
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
7-1 ® eClieck M
tiCCURt\'\tITRfCti
EXTERIOR RESEARCH &DESIGN, LLC.
Certificate of Authorization#9503
TRINITY ERD 353 CHRISTIAN STREET,UNIT#13
OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
GAF Evaluation Report 01506.01.08-1117
1 Campus Drive FL10124-R15
Parsippany, NJ 07054 Date of Issuance:01/03/2008
Revision 17:03/31/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by:
Robert J.M.Nieminen P.E. ����i��'� %�;• The facsimile seal appearing was authorized by Robert Nieminen,
j ��"L`tttsk ' P.E.on 03/31/2015.This does not serve as an electronically signed
Florida Registration No.59155,Florida DCA ANE1983 document.Signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E. does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
F)o
TRINITY I ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following
sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008
1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995
3. REFERENCES:
Enti Examination Reference Date
GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012
PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTM D3462 99NK43835 01/12/2000
UL(TST 1740) TAS 107 94NK9632 03/29/2000
UL(TST 1740) ASTM D3462 01NK06632 02/02/2001
UL(TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001
UL(TST 1740) ASTM D3161 01NK37122 12/18/2001
UL(TST 1740) ASTM D3462 01NK37122 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(TST 1740) ASTM D3161 03CA5367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26444 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST 1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1740) ASTM D3462 04NK22009 05/06/2005
UL(TST 1740) ASTM D3161 04NK22009 05/09/2005
UL(TST 1740) ASTM D3462 05NK27924 02/10/2006
UL(TST 1740) ASTM D3161 05NK27924 02/11/2006
UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006
UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006
UL(TST 1740) ASTM D3462 06CA31603 12/01/2006
UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006
UL(TST 1740) ASTM D3161 07NK05228 03/13/2007
UL(TST 1740) ASTM D3161 06CA31611 04/04/2007
UL(TST 1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007
UL(TST 1740) ASTM D3161,D7158,D3462 OBCA06100 03/13/2008
UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008
UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161,D7158,D3462 1OCA35554 03/05/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010
UL(TST 1740) ASTM D3462 IOCA07264 05/27/2010
UL(TST 1740) ASTM D3462 IOCA11953 10/29/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1ONK12070 11/04/2010
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-R17
Certificate of Authorization#9503 F1.10124-1115
Revision 17:03/31/2015
Page 2 of 5
QOTRINI-rYIERD
Enti Examination Reference Date
UL(TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011
UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012
UL,I.I.C.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013
UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013
UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013
UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013
UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 11/21/2014
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 02/06/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 02/20/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 02/19/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Shafter,CA 01/05/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 02/23/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Minneapolis,MN 02/16/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 02/10/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 02/11/2015
UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 03/05/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 02/25/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 03/07/2015
UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 03/02/2015
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Marquis®WeatherMax®,Royal Sovereign®and Sentinel®are a fiberglass reinforced 3-tab asphalt roof shingles.
4.1.2 Camelot®, Camelot® II, Country Mansion® II, Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Monaco®, Sienna®,
Timberline American Harvest®, Timberline® ArmorShieldTM II, Timberline® Natural Shadow®, Timberline HD®,
Timberline® Cool Series, Timberline Ultra HD® and Woodland® are fiberglass reinforced, laminated asphalt roof
shingles.
4.1.3 Slateline®is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip&Ridge Shingles:
4.2.1 Seal-A-Ridge® Ridge Cap Shingles,Seal-A-Ridge®IR Impact-Resistant Ridge Cap Shingles and Timbertex®Premium Ridge
Cap Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Starter Strips:
4.3.1 Pro-Start® Starter Strip Shingles and WeatherBlockerTI Premium Eave/Rake Starter Strip are starter strips for asphalt
roof shingles.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to
ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to
Vasd=150 mph(V„1t=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph
(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-R17
Certificate of Authorization#9503 FL10124-1115
Revision 17:03/31/2015
Page 3 of 5
TRINITY f ERD
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and
F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally
Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6.2 Starter Shingles:
6.2.1 Installation of Pro-Start Starter Strip Shingles and WeatherBlocker Premium Eave/Rake Starter Strip shall comply with the
manufacturer's current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four
(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions:
➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, and Woodland require minimum five (5)
nails per shingle.
➢ Slateline requires minimum six(6)nails per shingle.
6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required. Contact
the shingle manufacturer for details.
6.4 Hip&Ridge Shingles:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles and Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles shall comply with
the manufacturer's current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per
shingle and nominal 0.25-inch diameter beads of Henkel"Loctite PL S30 Roof&Flashing Sealant".
11'5" Sealant
1° (292 mm) 1" Seilante
(25 MM) (25 mm) Enduit d'etanche'Rd
12"
N ail (305 mm)
N
Clavo
6 518"-7-5/8" Clouer
(168-194 mm)
12"
(305 mm)
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-R37
Certificate of Authorization#9503 FL10124-R15
Revision 17:03/31/2015
Page 4 of 5
TRINITY ERD
6.4.2 Installation of Timbertex Premium. Ridge Cap Shingles shall comply with the manufacturer's current published
instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NPI
Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.
"e
88salEirY1
�°(2-&2 mm-t 1' Snll�n►¢
rnrn 25 rnn; r-ridLit d'ftrich 16
i
Maki
iT '
{Jaber rrm)
WM rmhl.
12"
{305 rnng
6.4.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(847)664-3281
- END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1117
Certificate of Authorization 49503 FL10124-R35
Revision 17:03/31/2015
Page 5 of 5
{it
Ouelness- •. 1 1' t 1
Florida Departmentof BCIS Home I Log In User Registration I Hot Topics ( Submit Surcharge I Stats&Facts Publications I FBC Staff I BCIS Site Map Links Search l
Busines
Professi I Product Approval
i � USER:Public User
Regulation
Product Aooroval Menu>Product or ADDlication Search>Application List>Application Detail
r. FL# FL10626-R12
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany,NJ 07054
(973)872-4421
lindareith@tiinityerd.com
Authorized Signature Beth McSoriey
lindarelth@trinityerd.com
Technical Representative Beth McSorley(current)
Address/Phone/Email 1 Campus Drive
Parsippany,NJ 07054
(973)872-4421
bmcsorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida _
Professional Engineer
Ed Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 11/12/2016
Validated By John W.Knezevich,PE
© Validation Checklist-Hardcopy Received
Certificate of Independence FL10626 R12 COI 2015 01 COT Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM D6164 2005
ASTM D6757 2007
FM 4474 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 03/31/2015
Date Validated 04/08/2015
Date Pending FBC Approval 04/12/2015
Date Approved 06/23/2015
Summary of Products'
FL# 114odel,Number or Name Description
10626.1 JGAF Roof Underlayments Roofing underlayments for use in sloped roof systems
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10626 R12 II 2015 03 FINAL ER GAF Underlayments FL10626-
Approved for use outside HVHZ:Yes R12. df
Impact Resistant:N/A Verified By:Robert Nieminen PE-59166
Design Pressure:+N/A/-45.0 Created by Independent Third Party:Yes
Other:1.)The design pressure noted in this application relates to one Evaluation Reports
particular underiayment system for use under foam-on tile systems. FL10626 R12 AE 2015 03 FINAL ER GAF Underlayments; FL10626-
Refer to ER Section 5.6.4 for details.2.)Refer to ER Section 5 for other R12. df
Umits of Use. Created by Independent Third Party:Yes
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
= ® EChec
SCCUritYdt li rR fCti
1
EXTERIOR RESEARCH & DESIGN, LLC.
F)o Certificate of Authorization#9503
TRINITY I ERD 353 CHRISTIAN STREET,UNIT#13
OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
GAF Evaluation Report 01506.04.08-1112
1Campus Drive FL10626-1112
Parsippany, NJ 07054 Date of Issuance:04/25/2008
Revision 12:03/31/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
`,v�cat7r,Wryly--
����;�
Robert J.M.Nieminen P.E. , The facsimile seal appearing was authorized by Robert Nieminen,
1�ZOO•.••� P.E.on 03/31/2015.This does not serve as an electronically signed
Florida Registration No.59166,Florida DG4 ANE1983 f:' ,`'al document.Signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E. does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
QTRR1N11YiERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: GAF Roof Underlayments, as produced by GAF, have demonstrated compliance with the following
sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Uplift FM 4474 2004
1507.2.4,1507.2.9.2,1507.5.3, Physical Properties ASTM D1970 2009
1507.7.3
1507.2.3 Physical Properties ASTM D6757 2007
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
Entity Examination Reference Date
ERD(TST 6049) Physical Properties G12210.06.09 08/03/2009
ERD(TST 6049) Physical Properties G34150.08.11 11/14/2011
ERD(TST 6049) Physical Properties G40630.01.14-2B 01/07/2014
ERD(TST 6049) Physical Properties G46160SC 04/14/2014
PRI(TST 5878) Physical properties GAF-026-02-01 03/26/2002
PRI(TST 5878) Physical properties GAF-027-02-01 03/26/2002
PRI(TST 5878) Physical properties GAF-042-02-02 03/12/2004
PRI(TST 5878) Physical properties GAF-042-02-01 06/03/2005
PRI(TST 5878) Physical properties GAF-154-02-01 02/06/2007
PRI(TST 5878) Physical properties RGM-023-02-01 02/09/2007
PRI(TST 5878) Physical properties ELK-311-02-01 09/11/2007
PRI(TST 5878) Physical properties GAF-238-02-01 03/03/2010
PRI(TST 5878) Physical properties GAF-275-02-01 11/11/2010
PRI(TST 5878) Physical properties GAF-349-02-01 06/19/2012
PRI(TST 5878) Wind Uplift GAF-434-02-01 09/16/2013
PRI(TST 5878) Wind Uplift GAF-434-02-03 09/16/2013
PRI(TST 5878) Wind Uplift GAF-434-02-04 09/16/2013
ITS(TST 1509) Physical properties 3077464-002 09/14/2005
ITS(TST 1509) Physical properties 3077464-02 01/09/2006
UL(TST 1740) Physical properties 02NK22569 06/04/2002
UL(TST 1740) Physical properties IONK11990 05/18/2011
Miami-Dade(CER 1592) HVHZ compliance 13-1104.05 02/20/2014
Miami-Dade(CER 1592) HVHZ compliance 13-1104.11 03/06/2014
Miami-Dade(CER 1592) HVHZ compliance 14-1022.26 02/05/2015
ICC-ES(EVL2396) IBC compliance ESR-1322 01/01/2014
UL,LLC.(QUA 9625) Quality Control Inspect,File R10689,Stockton,CA 11/12/2014
UL,LLC.(QUA 9625) Quality Control Inspect,File R10689,Hickory,NC 03/04/2015
UL,LLC.(QUA 9625) Quality Control Inspect,File R10689,Mt.Vernon,IN 01/16/2015
UL,LLC.(QUA 9625) Quality Control Inspect,File R10689,Pryor,OK 02/05/2015
4. PRODUCT DESCRIPTION:
4.1 Self-Adhering Underlavments:
4.1.1 Liberty— SBS Self-Adhering Base/Ply Sheet is a smooth-surfaced,fiberglass-reinforced, self-adhering SBS modified
bitumen roof underlayment.
4.1.2 StormGuard®Film Surfaced Leak Barrier is a film-surfaced,fiberglass-reinforced,self-adhering SBS modified bitumen
roof underlayment. StormGuard® Film Surfaced Leak Barrier is also used as a secondary water barrier to seal roof
decks.
Exterior Research and Design,I.I.C. Evaluation Report 01506.04.08-R12
Certificate of Authorization#9503 FL10626-1112
Revision 12:03/31/2015
Page 2 of 8
TRINITY
ERD
4.1.3 UnderRoofTM 2 Polyester-Surfaced Leak Barrier is a spun-bond-glass-reinforced-polyester-mat-surfaced, composite-
reinforced,SBS self-adhering modified bitumen roof underlayment.
4.1.4 UnderRoof m HT High Temperature Leak Barrier is a polyester-mat-surfaced,fiberglass-reinforced,self-adhering SBS
modified bitumen roof underlayment.
4.1.5 WeatherWatch® Mineral Surfaced Leak Barrier is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen roof underlayment. WeatherWatch® Mineral Surfaced Leak Barrier is also used as a secondary
water barrier to seal roof decks.
4.1.6 WeatherWatch® XT Mat Surfaced Leak Barrier is a coated-mat-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen roof underlayment.
4.2 Mechanically Fastened Underlayments:
4.2.1 VersaShield® Fire-Resistant Roof Deck Protection is a non-asphaltic,fiberglass-based roof underlayment and/or fire
barrier.
4.3 Asphalt-Applied Underlayments:
4.3.1 Ruberoid® Mop Granule is a granule-surfaced, polyester-reinforced, asphalt-applied SBS modified bitumen roof
underlayment.
4.3.2 Ruberoid® Mop Granule FR (formerly Ruberoid® Mop 170 FR) is a granule-surfaced, polyester-reinforced, asphalt-
applied SBS modified bitumen roof underlayment.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way,the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory or test
report from accredited testing agency for fire ratings of this product.
5.4 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop GAF Roof Underlayments are follows:
TABLE 1: ROOF COVER OPTIONS
Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes& Slate or
Shingles Shingles Simulated Slate
VersaShield®Fire-Resistant Yes No No No No No
Roof Deck Protection
Liberty—SBS Self-Adhering
Base/Ply Sheet Yes No No No No No
StormGuard®Film Surfaced
Leak Barrier Yes No No Yes No No
UnderRoof'2 Polyester- Yes
Surfaced Leak Barrier Yes Yes No No Yes
See 5.5.1
UnderRoof-HT High Yes
Temperature Leak Barrier No No Yes No No
WeatherWatch®Mineral Yes No No No No No
Surfaced Leak Barrier
WeatherWatch®XT Mat
Surfaced Leak Barrier Yes No No No No No
Ruberoid®Mop Granule Yes Yes Yes No Yes Yes
See 5.5.1
Ruberoid®Mop Granule FR Yes Yes Yes No Yes Yes
See 5.5.1
Exterior Research and Design,LLC. Evaluation Report 01506.04.08-1112
Certificate of Authorization#9503 FL10626-R12
Revision 12:03/31/2015
Page 3 of 8
��TRINI-rYl ERD
5.5.1 "Foam-On Tile" is limited to use of the following unless tensile adhesion/long term aging data from-an accredited
testing laboratory is provided.
Underlayment(s) Adhesive Option(s)
UnderRoof"2 Polyester-Surfaced Leak Barrier 3M'"2-Component Roof Tile Adhesive AH-160(FL6332)
Ruberoid°Mop Granule;Ruberoid®Mop Granule FR Dow TileBond(FL717)
5.6 Allowable substrates are noted below:
5.6.1 LibertvT1 SBS Self-Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; UnderRoofT" 2 Polyester-
Surfaced Leak Barrier; UnderRoofT" HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced Leak
Barrier and WeatherWatch®XT Mat Surfaced Leak Barrier.Self-Adhered to Deck:
➢ New untreated plywood;
➢ Existing untreated ASTM D41 primed plywood.
Ruberoid®Mop Granule and Ruberoid®Mop Granule FR.Asphalt-Applied to Deck:
➢ ASTM D41 primed structural concrete.
5.6.2 Liberty" SBS Self-Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; UnderRoofT" 2 Polyester-
Surfaced Leak Barrier: UnderRoof" HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced Leak
Barrier and WeatherWatch® XT Mat Surfaced Leak Barrier. Self-Adhered to Mechanically Attached Base
Underlavment:
➢ ASTM D226,Type II felt.
➢ StormSafeT"Anchor Sheet
Ruberoid® Mop Granule and Ruberoid® Mop Granule FR. Asphalt-Applied to Mechanically Attached Base
Underlavment:
➢ GAFGLAS®#80 UltimaT"Base Sheet;
➢ Ruberoid®20 Smooth.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012(04-12)or as detailed below.
5.6.3 Bond to Other Substrate Types:
➢ ASTM D41 primed metal(flashing metal,valley metal,etc.)
5.6.4 Wind Resistance for Underlavment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for
determination of design wind loads.
5.6.4.1 Maximum Design Pressure=-45 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)ASTM D41
Underlayment: UnderRoofT"2 Polyester-Surfaced Leak Barrier,self-adhered
5.6.4.2 Maximum Design Pressure=-45 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: GAFGLAS®#80 UltimaT"Base Sheet or Ruberoid®20 Smooth mechanically attached with 12 ga.,min.
1.25-inch long ring shank nails through 32 ga., 1-5/8 inch diameter tin caps spaced 9-inch o.c.at the
4-inch wide side laps and 9-inch o.c.at two(2),equally spaced,staggered center in the field of the
sheet.
Top Layer: Ruberoid® Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 lbs/square.
Exterior Research and Design,LLC. Evaluation Report 01506.04.08-1112
Certificate of Authorization 119503 FL10626-1112
Revision 12:03/31/2015
Page 4 of 8
TRINITY ERD
5.6.4.3 Maximum Design Pressure=-45 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: GAFGLAS®#80 UltimaT""Base Sheet or Ruberoid®20 Smooth mechanically attached with 12 ga.,min.
1.25-inch long ring shank nails through 32 ga., 1-5/8 inch diameter tin caps spaced 8-inch o.c.at the
4-inch wide side laps and 8-inch o.c.at three(3),equally spaced,staggered center in the field of the
sheet.
Top Layer: Ruberoid® Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 lbs/square.
5.7 Exposure Limitations:
5.7.1 Liberty— SBS Self-Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; UnderRoof1m HT High
Temperature Leak Barrier;WeatherWatch®Mineral Surfaced Leak Barrier and WeatherWatch®XT Mat Surfaced Leak
Barrier shall not be left exposed for longer than 30-days after installation.
5.7.2 VersaShield® Fire-Resistant Roof Deck Protection, UnderRoofT"" 2 Polyester-Surfaced Leak Barrier, Ruberoid® Mop
Granule and Ruberoid®Mop Granule FR shall not be left exposed for longer than 180-days after installation.
6. INSTALLATION:
6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Install self-adhering underlayments when ambient temperatures are minimum 45"F and rising.
6.4 All metal surfaces shall be primed with MatrixT"" 307 Premium Asphalt Primer or alternate GAF accepted ASTM D41
primer prior to application of self-adhering membranes.
6.5 VersaShield®Fire-Resistant Roof Deck Protection:
6.5.1 Install VersaShield® Fire-Resistant Roof Deck Protection in compliance with manufacturer's published installation
instructions and the requirements for ASTM D6757 underlayment in FBC Section 1507.2.3 for the type of prepared
roof covering to be installed. A double layer is required for 2:12<roof slope<4:12. No hammer tacks or staples are
permitted
6.5.2 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty'" SBS Self-Adhering
Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; UnderRoofTm 2 Polyester-Surfaced Leak Barrier;
UnderRoof m HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced or WeatherWatch® XT Mat
Surfaced Leak Barrier at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and
dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake,
install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the
underlayment and exposed decking. At other areas,install the leak barrier over the underlayment.
6.6 Liberty—SBS Self-Adhering Base/Ply Sheet:
6.6.1 Install Liberty- SBS Self-Adhering Base/Ply Sheet in compliance with manufacturer's published installation
instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof
covering to be installed.
6.6.2 The minimum and maximum roof slopes are%:12 and 6:12,respectively. Back-nailing is required when slope is 1:12
or greater. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 18"o.c.within 3-inch side
laps.
6.6.3 For non-tile applications,direct to deck:
For direct-bond to deck applications plywood shall be primed with Matrix—307 Premium Asphalt Primer or alternate
GAF accepted ASTM D41 primer at%to%gallon per square.
Prior to removal of release film, align sheets properly starting at the low-point of the roof(eave) with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes. Roll out sheet and allow to 'relax'for min. 30
minutes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the
eave and nail into place 12" o.c. Remove the top piece of release film and bond to substrate. Install primed drip
edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of Matrix—201 Premium
SBS Flashing Cement over drip edge.
Exterior Research and Design,LLC. Evaluation Report 01506.04.08-1112
Certificate ofAuthorization#9503 FL10626-R12
Revision 12:03/31/2015
Page 5 of 8
TTwN1_r' YjERD
Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Ensure
all end laps are staggered at least 18-inch apart.
Use a weighted lawn or linoleum roller to ensure complete adhesion to the substrate. Use a hand roller to firmly
bond side and end laps.
6.6.4 For non-tile applications,to mechanically attached anchor sheet:
Install ASTM D226,Type II felt in accordance with codified requirements or StormSafeT Anchor Sheet in accordance
with Section 6.6.
Install LibertyTM SBS Self-Adhering Base/Ply Sheet over the mechanically attached anchor sheet as noted above.
6.7 StormGuard®Film Surfaced Leak Barrier:
6.7.1 Install StormGuard®Film Surfaced Leak Barrier in compliance with manufacturer's published installation instructions
and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to
be installed.
6.7.2 Back-nailing is required. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c.
within 3-inch side laps.
6.7.3 For non-tile applications,direct to deck:
Prior to removal of release film, align sheets properly starting at the low-point of the roof(eave) with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and
bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load
requirements. Install 1/8-inch troweling of MatrixTm 201 Premium SBS Flashing Cement over drip edge.
Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Ensure
all end laps are staggered at least 18-inch apart.
Use a hand roller to firmly bond side and end laps.
6.7.4 For non-tile applications,to mechanically attached anchor sheet:
Install ASTM D226,Type II felt in accordance with codified requirements or StormSafeTm Anchor Sheet in accordance
with Section 6.6.
Install StormGuard®Film Surfaced Leak Barrier over the mechanically attached anchor sheet as noted above.
6.8 UnderRoof—2 Polyester-Surfaced Leak Barrier:
6.8.1 Install UnderRoofT1 2 Polyester-Surfaced Leak Barrier in compliance with manufacturer's published installation
instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof
covering to be installed.
6.8.2 The minimum and maximum roof slopes are 2:12 and 12:12,respectively. Back-nailing is required when slope is 4:12
or greater. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 12"o.c.within 4-inch side
laps.
6.8.3 For tile roof installations:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted herein as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to
the underlayment.
6.8.4 For non-tile applications,direct to deck:
Prior to removal of release film, align sheets properly starting at the low-point of the roof(eave) with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and
bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load
requirements. Install 1/8-inch troweling of Matrix—201 Premium SBS Flashing Cement over drip edge.
Continue upslope in a similar manner, maintaining minimum 4-inch side-laps and minimum 6-inch end-laps. Ensure
all end laps are staggered at least 3-feet apart. End laps shall be sealed with a 1/16th to 1/81h inch thick trowel
application of Matrix—201 Premium SBS Flashing Cement.
Use a hand roller to firmly bond side and end laps.
Exterior Research and Design,LLC. Evaluation Report 01506.04.08-R32
Certificate of Authorization#9503 FL10626-R12
Revision 12:03/31/2015
Page 6 of 8
"',JTR1N11Y1ERD
6.8.5 For non-tile applications,to mechanically attached anchor sheet:
Install ASTM D226,Type II felt in accordance with codified requirements or StormSafeT""Anchor Sheet in accordance
with Section 6.6.
Install UnderRoofm 2 Polyester-Surfaced Leak Barrier over the mechanically attached anchor sheet as noted above.
6.9 UnderRoofTM"HT High Temperature Leak Barrier:
6.9.1 Install UnderRoofT"' HT High Temperature Leak Barrier in compliance with manufacturer's published installation
instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof
covering to be installed.
6.9.2 The minimum and maximum roof slopes are 1:12 and 12:12,respectively. Back-nailing is required when slope is 4:12
or greater. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 12"o.c.within 4-inch side
laps.
6.9.3 For non-tile applications,direct to deck:
Prior to removal of release film, align sheets properly starting at the low-point of the roof(eave) with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and
bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load
requirements. Install 1/8-inch troweling of TopCoat®FlexSealT"'Caulk Grade over drip edge.
Continue upslope in a similar manner, maintaining minimum 4-inch side-laps and minimum 6-inch end-laps. Ensure
all end laps are staggered at least 3-feet apart.
Use a hand roller to firmly bond side and end laps.
6.9.4 For non-tile applications,to mechanically attached anchor sheet:
Install ASTM D226,Type II felt in accordance with codified requirements or StormSafeT"'Anchor Sheet in accordance
with Section 6.7.
Install UnderRoofT HT High Temperature Leak Barrier over the mechanically attached anchor sheet as noted above.
6.10 WeatherWatch®Mineral Surfaced Leak Barrier or WeatherWatch®XT Mat Surfaced Leak Barrier:
6.10.1 Install WeatherWatch®Mineral Surfaced Leak Barrier or WeatherWatch®XT Mat Surfaced Leak Barrier in compliance
with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC
Sections 1507 for the type of prepared roof covering to be installed.
6.10.2 WeatherWatch® Mineral Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-inch
wide rolls to seal plywood deck joints prior to installation of the primary underlayment system.
6.10.3 Back-nailing is required. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c.
within 4-inch side laps.
6.10.4 For non-tile applications,direct to deck:
Prior to removal of release film, align sheets properly starting at the low-point of the roof(eave) with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and
bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter"16 wind load
requirements. Install 1/8-inch troweling of Matrix—201 Premium SBS Flashing Cement over drip edge.
Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Ensure
all end laps are staggered at least 18-feet apart.
Use a hand roller to firmly bond side and end laps.
6.10.5 For non-tile applications,to mechanically attached anchor sheet:
Install ASTM D226,Type II felt in accordance with codified requirements or StormSafeT"Anchor Sheet in accordance
with Section 6.6.
Install WeatherWatch® Mineral Surfaced Leak Barrier or WeatherWatch® XT Mat Surfaced Leak Barrier over the
mechanically attached anchor sheet as noted above.
Exterior Research and Design,I.I.C. Evaluation Report 01506.04.08-1112
Certificate of Authorization#9503 F1.10626-1112
Revision 12:03/31/2015
Page 7 of 8
TRINITY I ERD
6.11 Ruberoid®Moa Granule;Ruberoid®Mop Granule FR:
6.11.1 Shall be installed in compliance with current GAF published installation requirements, subject to the limitations
herein.
6.11.2 Non-Tile Applications:
6.11.2.1 Fully adhere in ASTM D312,Type IV hot-asphalt to the substrates noted in Section 5.5. Side laps shall be minimum 4-
inch and end-laps minimum 6-inch wide,and offset end-laps minimum 3-feet from course to course. Side and end-
laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch
beyond the lap edge. Consult GAF instructions regarding back-nailing requirements.
6.11.3 Tile Applications:
6.11.3.1 Refer to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein.
6.11.3.2 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC.—QUA9625;(847)664-3281
-END OF EVALUATION REPORT-
Exterior Research and Design,U.C. Evaluation Report 01506.04.08-1112
Certificate of Authorization#9503 F1.10626-1112
Revision 12:03/31/2015
Page 8 of 8
` } , lit.
i n �professiotO 0 ;
Ira:.. ., N
Florida Depaivientof BCIS Home Log In User Registration l Hot Topics Submit Surcharge I Stats&Facts Publications FBC Staff BCIS Site Map Links l Search
Busines
Professi I Product Approval
USER:Public User
Regulation
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL6267-R10
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany, NJ 07054
(973)872-4421
lindareith@trinityerd.com
Authorized Signature Beth McSorley
lindareith@trinityerd.com
Technical Representative Beth McSorley(current)
Address/Phone/Email 1 Campus Drive
Parsippany,NJ 07054
(973)872-4421
bmcsorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/24/2017
Validated By John W. Knezevich,PE
© Validation Checklist-Hardcopy Received
Certificate of Independence FL6267 Rio COI 2016 01 COI Nieminen odf
Referenced Standard and Year(of Standard) Standard Year
ASTM G155 2005
TAS 100(A) 1995
TAS 110 2000
TAS 114,Appendix E 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/13/2016
Date Validated 04/18/2016
Date Pending FBC Approval 04/20/2016
Date Approved 06/08/2016
Summary of Products
FL# Model,Number or Name Description
6267.1 GAF Roof Ventilation Products Low profile roof ridge vents
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL6267 R10 II 2016 04 FINAL GAF Ventilation FL6267-
Approved for use outside HVHZ:Yes R10.1)df
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party: Yes
Other:Refer to ER Section 5 for Limits of Use. Evaluation Reports
FL6267 R10 AE 2016 04 FINAL GAF Ventilation FL6267-
R10.Ddf
Created by Independent Third Party:Yes
Back Fe.t
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here_.
Product Approval Accepts:
® eCheck
sccuritv.%L-rRICS'
EXTERIOR RESEARCH &DESIGN, LLC.
F)o Certificate of Authorization#9503
TRINITY I ERD 353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
GAF Evaluation Report 01506.02.06-1110
1 Campus Drive FL6267-R10
Parsippany, NJ 07054 Date of Issuance:02/28/2006
Revision 10:04/13/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections referenced herein.
DESCRIPTION: GAF Roof Ventilation Products
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robert J.M.Nieminen P.E. The facsimile seal appearing%vas authorized by Robert Nieminen,
iP.E.on 04/13/2016.This does not serve as an electronically signed
Florida Registration No.59166 Florida DCA ANE1983 S " ' "�;:r•. .
9 i 'i' ��✓l y;\.`rs document.Signed,sealed hardcopies have been transmitted to the
'F•,. Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
QO
TRINITY i ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: GAF Roof Ventilation Products, as produced by GAF, have demonstrated compliance with
the following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1506.5/1517.5.1 Corrosion Resistance(of nails) TAS 114,Appendix E 1995
1523.6.5.2.13 Wind Driven Rain TAS 100(A) 1995
1523.6.5.2.13.1 Physical Properties TAS 110 2000
2614.2 Weatherometer ASTM G155 2005
3. REFERENCES:
Entity Examination Reference Date
ATI(TST 1558) Physical Properties 01-49035.01 03/02/2004
ATI(TST 1558) Wind Driven Rain 01-44964.01 01/15/2004
ATI(TST 1558) Wind Driven Rain 60172.01-122-18 10/07/2005
ATI(TST 1558) Physical Properties 59665.02-106-31 09/16/2005
ATI(TST 1558) Wind Driven Rain 84608.01-106-18 11/12/2008
ATI(TST 1558) Wind Driven Rain A5250.01-109-18 02/18/2011
PRI(TST 5878) Weatherometer HBP-007-02-01 06/24/2004
PRI(TST 5878) Physical Properties HBP-002-02-01 06/06/2001
PRI(TST 5878) Wind Driven Rain HBP-01-02-01 11/02/2000
PRI(TST 5878) Wind Driven Rain BRY-021-02-01 12/31/2003
PRI(TST 5878) Physical Properties BRY-025-02-01 09/17/2004
PRI(TST 5878) Physical Properties GAF-138-02-06 02/09/2007
PRI(TST 5878) Wind Driven Rain GAF-138-02-04 02/09/2007
PRI(TST 5878) Wind Driven Rain GAF-310-02-01 07/07/2011
ETC Labs(TST 24 11) Physical Properties ETC-01-718-10379.0 01/16/2000
ETC Labs(TST 2411) Physical Properties ETC-03-718-14602.0 01/20/2004
ETC Labs(TST 2411) Physical Properties ETC-07-718-19959.0 09/27/2007
Miami-Dade(CER 1592) Various Various NCAs Current
Miami-Dade(CER 1592) Corrosion Resistance(of nails) Certification L 12-0614.08 06/26/2012
Miami-Dade(CER 1592) Corrosion Resistance(of nails) Certification L 12-0601.24 06/29/2012
Miami-Dade(CER 1592) Corrosion Resistance(of nails) Certification L 15-0421.09 05/07/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R15072,GAl 08/24/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R15072,GA2 11/05/2015
4. PRODUCT DESCRIPTION:
4.1 Cobra® Exhaust Vent is a low-profile attic ridge vent of mesh-construction for use in shingle roof systems.
The product measures 10%-inch wide supplied in 20 and 50 ft long rolls, and is supplied with corrosion
resistant 1%"coil nails or 2%"Smart Nails"
4.2 Cobra® Rigid Vent 3Tm is a plastic, low-profile attic ridge vent for use in shingle roof systems with 12-inch
width ridge caps. The product measures 13-13/16-inch wide supplied in 48-inch long sections, and is
supplied with 3-inch corrosion resistant ring shank nails.
4.3 Cobra® Rigid Vent 3'M - 9" is a plastic, low-profile attic ridge vent for use in shingle roof systems with 10-
inch width ridge caps. The product measures 11%2-inch wide supplied in 48-inch long sections, and is
supplied with 3-inch corrosion resistant ring shank nails.
Exterior Research and Design,LLC. Evaluation Report 01506.02.06-1110
Certificate of Authorization 119503 FL6267-R10
Revision 30:04/13/2016
Page 2 of 7
( 10.
TRINITY i ERD
4.4 Cobra® Snow Country'"' is a plastic, low-profile attic ridge vent with filter for use in shingle roof systems.
The product measures 13-13/16-inch wide supplied in 48-inch long sections
4.5 Cobra®Snow Country Advanced'"' is a plastic, low-profile attic ridge vent with filter for use in shingle roof
systems with 12-inch width ridge caps. The product measures 13-13/16-inch wide supplied in 48-inch long
sections,and is supplied with 3-inch corrosion resistant ring shank nails.
4.6 Cobra®Snow Country Advanced'"" -9" is a plastic, low-profile attic ridge vent with filter for use in shingle
roof systems with 10-inch width ridge caps. The product measures 11%:-inch wide supplied in 48-inch long
sections,and is supplied with 3-inch corrosion resistant ring shank nails.
4.7 Cobra® Ridge Runner® is a polypropylene plastic, low-profile attic ridge vent for use in shingle roof
systems. The product measures 11'/z-inch wide supplied in 20 ft long rolls, and is supplied with corrosion
resistant 1%"coil nails.
4.8 TruSlate® Ridge Vent is a plastic, low-profile attic ridge vent for use in TruSlate® roof systems. The
product measures 11.4-inch wide supplied in 48-inch long sections.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Minimum slopes are as follows:
Product Minimum Slope
Cobra® Exhaust Vent 2:12
Cobra® Rigid Vent 3'M 3:12
Cobra® Rigid Vent 37M-9" 3:12
Cobra®Snow CountryTM 3:12
Cobra®Snow Country Advanced TM 3:12
Cobra®Snow Country Advanced TM-9" 3:12
Cobra®Ridge Runner® 3:12
TruSlate® Ridge Vent 5:12
5.4 The maximum mean roof height for Cobra® Exhaust Vent, Cobra® Rigid Vent 3, Cobra® Rigid Vent 3 —9",
Cobra®Snow Country'"", Cobra®Snow Country Advanced"",Cobra®Snow Country Advanced TM—9",Cobra®
Ridge Runner®and TruSlate°Ridge Vent shall be 33 ft.
5.5 Installation shall result in minimum net free ventilation area requirements set forth in FBC Sections 1203.2.
When more than one level of roof ridge existing over a single attic space, use ridge vents only at the high
ridge.
6. INSTALLATION:
6.1 GAF Roof Ventilation Products shall be installed in accordance with GAF published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6_2 COBRA®EXHAUST VENT:
6.2.1 Chalk a cut-line 1-inch off each side of the ridge and cut a slot along the apex of the roof measuring 2-inch
(for truss construction) or 3%-inch (for ridge pole construction). The slot should terminate 6-inches from
each end and 12-inches from hip intersections or chimneys. Cut only the sheathing; do not cut trusses.
Figure A.
6.2.2 Unroll the vent along the entire length of the ridge, covering uncut 6-inch sheathing area on both ends.
Shorter lengths can be joined by caulking and butting the ends. Figure B.
Exterior Research and Design,I.I.C. Evaluation Report 01506.02.06-1110
Certificate of Authorization#9503 FL6267-R10
Revision 30:04/13/2016
Page 3 of 7
TRINITY�ERD
6.2.3 Apply a bead of polyurethane roof sealant to the underside of the entire perimeter of the vent and nail
with min. 2%-inch galvanized roofing nails at each corner and 10-inch o.c. Do not use excessive roof
cement,as it may result in shingle blistering.
6.2.4 Apply a bead of polyurethane roof sealant in the shape of a"C"to the underside of the entire perimeter of
the cap shingles, and install cap shingles directly over the vent using Smart NaiISTM or 1%-inch corrosion
resistant coil nails(supplied with the vent). Figure C. Do not use excessive roof cement,as it may result in
shingle blistering.
6.2.5 Cobra® Exhaust Vent (hand nail version) and Cobra® Exhaust Vent (nail gun version) have a %-inch or 5/8-
inch nominal thickness, respectively, to facilitate ventilation. Care shall be taken not to crush or compact
the product during installation. Figure D.
Hand-Nail Version Nail Gun Version
6_3 COBRA® RIGID VENT 3T"°, RIGID VENT 3 T-911
, SNOW COUNTRY . SNOW COUNTRY ADVANCEDT"'AND SNOW COUNTRY
ADVANCED T11-911
'
6.3.1 Mark-off and cut the slot opening as follows, ensuring that the ends of the opening stop at least 6-inch
from any end walls and at least 12-inch from hip and ridge intersections or chimneys.
➢ No Ridge Board: Cut a 7/8-inch opening on each side of the ridge(Figure A).
➢ With Ridge Board: Cut a 1-5/8-inch opening on each side of the ridge(Figure B).
7/8 1/8"
Z
9 I I I
1/a� 31/4„
No Ridge Board With Ridge Board
Exterior Research and Design,LLC. Evaluation Report 01506.02.06-R10
Certificate of Authorization#9503 FL6267-R10
Revision 10:04/13/2016
Page 4 of 7
(_)o
TRINITY}ERD
6.3.2 Sealant: Apply a bead of silicone caulking or roof cement to the underside of the outer baffle along both
edges and at exposed ends,ensuring the outside edges where the vent meets the shingles are sealed with
the caulk or flashing cement.
6.3.3 Vent Placement: Starting at one end of the slot,place,center and conform the Cobra®rigid vent over the
slot with the vent firmly against the roof surface,ensuring the vent extends past the slot opening by at
least 6-inch.
6.3.4 Fasteners: For Cobra® Rigid Vent 3T'",Cobra®Rigid Vent 3 T-9",Cobra"Snow Country Advanced'"and
Cobra®Snow Country Advanced TM-9"only, use the 3"corrosion resistant ring shank nails(included). For
Cobra®Snow CountryTM,use corrosion resistant nails at least 13/-inch or longer. Nails must always
penetrate through plywood decks or at least 3/-inch into wood planks. NOTE:GAF recommends 3-inch
corrosion resistant ring shank nails for increased uplift resistance.
6.3.5 Spacing: Attach the vent section through the pre-molded nailing holes located at 3, 12,24,36 and 45-inch
from the start of each 48-inch vent piece.
6.3.6 Joints: Apply the subsequent Cobra®rigid vent sections over the length of the ridge using the
overlap/underlap tabs.
6.3.7 Ridge Shingles: Install ridge shingles in accordance with shingle manufacturer's published installation
instructions, using corrosion resistant nails detailed in 6.3.4. A nail line is inscribed on top of the Cobra®
rigid vent to serve as a guide.
6.4 COBRA®RIDGE RUNNER®
6.4.1 Cut slot per 6.3.1.
6.4.2 Tear a 1-foot section to be used as a template for laying the vent out(Figure E-G)and center the template/
locator over the ridge cap shingles at the beginning of the vent slot. Note the location of the baffle(Figure
H). Make sure to do this at both ends of the installation.
. ply.
6.4.3 Measure the distance from the edge of the roof slot to the exterior baffle (D). Establish a chalk line along
one side of the ridge (Figure 1). Unroll the vent and use the included 1-3/4-inch pneumatic corrosion
resistant roofing nails to attach the first side of the ridge vent with the exterior of the baffle aligned with
the chalk line (Figure J). Proceed with using the 1' interval EasyTearTM system to custom size the vent to
the appropriate length. If the EasyTear'M system can not be utilized, use a utility knife to size the vent. Nail
gun targets are embossed on the part as a guide for property attaching vent to the roof.The vent should
be fastened on 6-inch centers(Figure K).
Exterior Research and Design,I.I.C. Evaluation Report 01506.02.06-R10
Certificate of Authorization#9503 FL6267-R10
Revision 10:04/13/2016
Page 5 of 7
1
OTRRINITYIERD
1 1
,< 6"
D
CHALK LINE
I 1
O �
� O
6.4.4 NOTE: When fastening the vent and cap shingles, be sure that the included 1 3/4-inch corrosion resistant
coil nails completely penetrate plywood or provide at least 3/4-inch penetration into wood planks. In the
case they do not, you must use alternate corrosion resistant nails that provide the required penetration.
Proceed with attaching the other side of the vent. When beginning to nail down the second side, do NOT
begin at the end; begin between the first and second one-foot sections and then return to fasten the first
one-foot section.This will allow for proper fit.
6.4.5 Install ridge shingles in accordance with shingle manufacturer's published installation instructions, using
the nail-lines on top of the ridge vent for proper lapping.
6.5 TRUSLATE11 RIDGE VENT:
6.5.1 DO NOT use on hips.
6.5.2 Intall TruSlate®Ridge Vent before installing the field slates.
6.5.3 After determining the total length of TruSlate® Ridge Vent required (for proper ventilation),determine the
necessary slot opening. Mark-off and cut the slot opening, ensuring the ends of the opening stop at least
6-inch from any end walls and at least 12-inch from hip and ridge intersections or chimneys.
Roofs without a ridge board:Cut a 7/8-inch opening along the ridge on each side(Figure A).
Roofs with a ridge board: Cut a 1-5/8-inch opening along the ridge on each side(Figure B).
Fig. A Fig. B
(41 MM)JW 1%8(41 mm)
(22 mm)7/8 7/8"(22 mm)
3Y;(82 mm)
With Ridge Board
V/4"(44 mm)
No Ridge Board
6.5.4 Install an 18-inch wide section of ASTM D1970 self-adhering leak barrier (holding Florida Statewide
Product Approval or Approved on a Local Basis) from the edge of the ridge slot extending down towards
the roof deck on both side of the slot.
Exterior Research and Design,I.I.C. Evaluation Report 01506.02.06-1110
Certificate of Authorization#9503 FL6267-R10
Revision 30:04/13/2016
Page 6 of 7
TiTRINIT'Y!ERD
6.5.5 Place the TruSlate® Ridge Vent over the ridge slot, "peaked" and centered over the ridge slot, and attach
using minimum 3-inch long corrosion resistant ring-shank nails through the pre-molded nail holes on the
vent, located 3-inch from the ends and 9-inch o.c. Fasteners shall penetrate through plywood decks or
embed minimum%-inch into wood plank decks.
6.5.6 Continue over the length of the ridge, utilizing the male/female connectors to connect units. Ensure the
finished ends include the pre-molded end caps. Cover all exposed nail heads on the vent with silicone
caulk. Intall a bead of exterior grade silicone sealant at the downslope leading edges of the ridge vent, at
the junction of the leading edge and the leak-barrier below.
6.5.7 Install the top course of TruSlate® field slates, UnderBlockTM UV & Moisture Barrier and TruSlate® trim
slates in accordance with GAF published installation instructions. Intall TruSlate®trim slates with 10-inch
exposure using minimum 1-5/8-inch long deck screws through pre-drilled holes,through the ridge vent to
engage the wood deck.
Deck-Armors'
Roof Deck Protection \
18" w°
(457mmi 257 mm
Weather Watcho at
StarmGuard®Leak Barrier
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 QA
requirements.
9. QUALITY ASSURANCE ENTITY:
UL, LLC.—QUA9625;(847)664-3281
-END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report 01506.02.06-1110
Certificate of Authorization#9503 FL6267-R10
Revision 10:04/13/2016
Page 7 of 7