r FL# j J FL14849-R2
Application Type Revision
Code Version 2014
Application Status �.Approve.d',_,.-�'
Comments
Archived _
Product Manufacturer Custom Window Systems Inc.
Address/Phone/Email 1900 SW 44th Avenue
Ocala,FL 34474
(352)368-6922
ekoss@cws.cc
Authorized Signature Koss Erin
ekoss@cws.cc
Technical Representative Erin Koss
Address/Phone/Email 1900 SW 44th Ave.
Ocala,FL 34474
(352)368-6922 Ext 291
ekoss@cws.cc
Quality Assurance Representative Jay Lathrop
Address/Phone/Email 1900 SW 44th Ave.
Ocala,FL 34474
(352)368-6922 Ext 291
jlathrop@cws.cc
Category Exterior Doors
Subcategory Sliding Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
'W. Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Lucas Turner
the Evaluation Report
Florida License PE-58201
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 07/21/2020
Validated By Steven M.Urich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL14849 R2 COI EvalReD CWS-643B(SGD-8940.XXXX,70DP,ND.odf
Referenced Standard and Year(of Standard) Standard Vear
AAMA/WDMA/CSA 101/I.S.2/A-440-05 2005
ASTM E1300-04 2004
Equivalence of Product Standards
Certified By
Sections from the Code
h4s://www.floridabuilding.org/pr/pr�_app
__4tl.aspx?param=wGEVXQwtDquHlFzfePouW... 4/21/2016
1)U111111%%-uut:VMme Page 2 of 2
Product Approval Method Method I Option D
Date Submitted 04/1412015
Date Validated 04/15/2015
Date Pending FBC Approval 04/19/2015
Date Approved 06/2312015
Summary of Products
FL# NOqe1,,Wdmbercsr Name Description
14849.1 940,Multi Track,Non- SGD-8940,Multi Track,Sliding Glass Door,Non-Impact
impact.
Installation Instructions
t`A"-p roved for use in HVHZ-No FL14849 R2 11 CWS-6438(SGD-8940.XXXX,70DP,
Approved for use outside HVHZ-.Yes Nl).od
Impact Resitstant.No Verified By:Lucas Turner 58201
Design Pressure.+70/-70 Created by Independent Third Party:Yes
Other.Multi Track configurations(see installation Evaluation Reports
drawings),DP+/-70 psf.Glass complies to ASTM E1300- FL14a49 R2 AE EvalRep CWS-6438(SGD-8940, XXXX,
04. 70DP.
Nl).Pdf
Created by Independent Third Party:Yes
Back PR
Contact u ::iogo North Mone Street,Tallahassee FL 32399 Phone.-850-487-2824
The State of Florida Is an AA/EEO employer.Copvdqkt 2007-2013 State of Florida,::Privacy Staternent::Acces-s-IbUlty statement :Refund statemen
Under Florida taw,email addresses are public moords.If you do not want your e-mail address released In response to a public-records request do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.if you have any questions,please contact 850.487.1395."Pursuant to
section 455.275(1),Florida Statutes,effective October 1,2012,licensers Homed under Chapter 455,F.S.must provide the Department with an email address If
they have one.The emaMs provided may be used for official communication with the licensee.However email addresses are public record.It you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,FS.,please crick fkqM.
product Approval Accepts:
MEMO
ht4)s://www.floridabuilding.org/pr/pT _app-Atl.aspx?param=WGEVXOwtDOUT41 F�ff--Plrli-ul A 1-)11-)A 1
GENERAL NOTES: J/'t7nRy�jmtlf�
t.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED I�iJVi fhiDt`,�5UVUS/TlEU1l5
TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT 1900 SW 44TH AVE.
EDITION. OCALA,FLORIDA 34474
2.GLAZING OPTIONS:(SEE SHEET 4) WWW.CWS.CC
3.APPROVED CONFIGURATIONS INCLUDE BUT ARE NOT LIMITED TO:
"XO","ox","XX","oxo° "xxx' "Oxxo","xxxx", 8940 PVC SLIDING
"PX","PXX","Pxxv,"Pxxxx%"PXXP","PXXXXP","PXXXXXXP% GLASS DOOR
"PXXXXXXXXP"
2 TRACK,3 TRACK,4 TRACK N(311l4MPACT
199"FRAME WIDTH 4.DESIGN PRESSURE RATING(SEE SHEET 2):
-NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND r
49 St8" 415/8' GLASS TABLES ASTM E-1300.04, N
MAX.PANEL WIDHT GLASS DLO -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER
INFILTRATION TEST PRESSURE AND GLASS TABLES _ a ;: 0
A ASTM E-130004, N w
`— 5.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED
IN THE DESIGN OF THIS PRODUCT,SEE SHEETS 8.9 FOR ANCHOR a)
i DETAILS. WINDLOAD DURATION FACTOR Cd-1.5 WAS USED FOR WOOD m m p
! ANCHOR CALCULATIONS. a o to
87"
f o o j
MAX. 8.NOT APPROVED FOR IMPACT RESISTANCE,IMPACT PROTECTIVE a ¢ O w
HEIGHT B } B SYSTEM IS REQUIRED IN WIND BORNE DEBRIS REGION, a a a
a
7.ALL FRAMES ARE PROCESSED AND SCREWED TOGETHER. PVC VENTS a a s
93 1/2" X X X C Bfi tl2° ARE FULLY WELDED. q p W
MAX. I 8 GLASS Dl0
( 8.SERIES/MODEL DESIGNATION SGD-8940. p
D
PANEL ..
HEIGHT (! S 9.THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING: ¢ Z
j f ( X=OPERABLE SASH,0#FIXED SASH,P=POCKET/HOOKSTRIP ``
,,e'°P�OREV
B
8 } + ! 9 10 OCA710N.ALLOUTS APPLY TO ALL CONFIGURATIONS INA SIMILAR yZ.Cj',yt0 hrs
j No 58201 'AM
f( 11.WEEP SLOTS=1/4"x 1-114"LOCATED W FROM BOTH ENDS. s y
F �EA_ A� 1:10' STATE OF :'4U`C'.
Lucas A. 4,�5, .<,o N:;;. ���•
Tumer '
2015-04-03
16:14-04:00
4/3/2016
LUCAS A.TURNER,P.E.
FL PE#58201
1239 JABARA AVE.
NORTH PORT,FL 34288
PH.941-380-1574
SiTDESCRPTO
TABLE OF CONTENTS GENERAL NOTES AND
ELEVATIONS
GENERAL NOTES&ELEVATIONS.....1 MAX. PANEL SIZE DESIGN PRESSURE RATING IMPACT RATING i Y: .
COMPARATIVE ANALYSIS..................2
SECTION VIEWS..................................3 SEE COMPARATIVE ANALYSIS ADE 08/24/11
BOM&GLAZING DETAIL__.................4 48.5/8„x 93.112" NONE
EXTRUSIONS.......................................5 CHART, SHEET 2 CWS-643 e
TRACK WIDTHS........„.........................8
ANCHOR SCHEDULE&NOTES..........7 (4)PANELS SHOWN,UNLIMITED NUMBER OF PANELS IS ALLOWABLE AS LONG AS SC ` SHEET
INSTALLATION DETAILS..................B-9 INDIVIDUAL PANELS DO NOT EXCEED PANEL SIZE AS SHOWN. 1:30 1 OF 9