Loading...
HomeMy WebLinkAboutProduct Approval (2) Florida Building.Code Online R E C E I V D JAN 7017 1(20/17,7:56 AM Sig R l BCIS Home Log In I User Registration I Hot Topics ; Submit Surcharge I Stats&Facts I Publications I FBC Staff BCIS Site Map Links Search Florida t r °.:�Product Approval USER:Public User do Product Approval Menu>Product or Agolication Search>Apolication List>Application Detalt e • a FL# FL9777-R7 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email. One Owens-Corning.Parkway. Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscoming.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R.Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden Validation Checklist-Hardcopy Received Certificate of Independence FL9777 R7 COI OCR14002 4A FBC 2014 Evaluation Report Weatherlock Non-HVHZ-final,pdf Referenced Standard and Year(of Standard) Standard Year ASTM D 1970 2009 ASTM G 155 2005 TAS 103 1995 UL 1897 2004 https:JJwww.floridabuilding.orgJprJpr_app_dtf.aspxIparam=wGEVXQwtDgtgkcMGblcW71%2fZr7gdugvKdKYuFvzTOfA%3d Page 1 of 3 Florida.Building.Cade Online 1/20/1.7,.7:66:AM. Equivalence of Product Standards Certified By -Sections.from.the-Code Product Approval Method Method 1 Option D Date Submitted 0.4/19/2016. Date Validated 04/20/2016 Date Pending FBC Approval 04/21/2016 Date Approved 06/08/2016 Summary of Products FL# Model, Number or Name Description 9777.1 Weatherlock G Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 R7 II OCR14002 4A FBC 2014 Evaluation Report Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-final.pddf Impact Resistant:.N/A. Verified-&y:.Zachary R..Priest-74021 Design Pressure: N/A Created by Independent Third Party:Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 R7 AE OCR14002 4A FBC 2014 Evaluation Report Weatherlock Non-HVHZ-final.pdf Created by Independent Third Party: Yes 9777.2 Weatherlock MAT Waterproofing Underlayment Limits of UseInstallation Instructions Approved for use in HVHZ: No' FL9777 R7 II QCR14002.4A FBC 2014 Evaluation Report Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-final.pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other:See eva_luat_io_n report for limits of use. Evaluation Reports 1�1_071_ R7 AE.QCR14002 4A FBC 2014 Evaluation Rep= Weatherlock Non-HVHZ-final pdf Created by Independent Third Party: Yes 9777.3 WeatherLock Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 R7 II OCR14002.4A FBC 2014 Evaluation Repos Approved for use outside HVKZ:Yes Weatherlock Non-HVHZ-final pdf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party:Yes Other: See evaluation report for limits of use.. Evaluation Reports FL9777 R7 AE OCR14002.4A FBC 2014 Evaluation Report Weatherlock Non-HVHZ-final pdf Created by Independent Third Party:Yes 9777.4 WeatherLock Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9777 R7 II QCR14002 4B FBC 2014 Evaluation Report Approved for use outside HVHZ: No Weatherlock Metal HVHZ-finalpdf Impact Resistant: N/A Verified By: Zachary R. Priest,.PE-74021 Design Pressure: N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluations Reports FL9777 R7 AE QCR14002 4B FBC 2014 Evaluation Report Weatherlock Metal HVHZ-final pdf Created by Independent Third Party:Yes 9777.5 WeatherLock Specialty Tile&MetalWeatherproofing Underlaym. pQj Limits of Use Installation Instructions https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtgkcMGb]cW71%2fZr7gdugvKdKYuFvzTOfA%3d Page 2 of 3 Florida Building Code Online 1/20/17,7:56 AM Approved for use in HVHZ: No FL9777 R7 II OCR14002.4A FBC 2014 Evaluation Report Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-final.odf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: +0/-105 Created by Independent Third Party: Yes Other: See evaluation report for limits,of use. Evaluation Reports FL9777 R7 AE OCR14002.4A FBC 2014 Evaluation Report Weatherlock Non-HVHZ-final.Ddf Created by Independent Third Party: Yes 0 rte,;: Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an WEED employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement,::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 856.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you area licensee under Chapter 455,F.S., please click here. ProductApproval Accepts: ® IBJ Ek -ka. Credit Card Safe https://www.floTidabuilding.oTg/pr/pT app-�itl:aspx?param=wGEVXQwtQgtgkcMGblcW71%2fZr7gdugvKdKYuFvzTOfA%3d Page 3 of 3 Certificate of Authorization No. 29824 CREEK 17520 EdinburghDrive Tampa, FL 33636477 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE V EDITION(2014) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued April 19,2016 1 Owens Corning Parkway Toledo,OH 43657 (800)438-7465 www.owenscoming.com Manufacturing Location: Brentwood;NH- Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: U nderlayments Code Sections: 1:504.3.1,1507.2.4, 1507.2.8, 1507.2.9.2,1507.3.3,1507.4.5,1507.4.5.2,1507.5.3, 1507.5.3.2,1507.7.3, 1507.7.32 Properties: Physical properties REFERENCES ED& Report No. Standard Year PRI Construction Materials Technologies(TST6049) NEI-039-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) NEI-042-02-01 REV2 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) NEI-045-02-0t TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 ASTM G 155 2005a PRI Construction.Materials Technologies(TST6049) NEI-053-02-01. TAS1.03. 1995. PRt Construction Materials Technologies(TST6049) NEI-053-02-04 ASTM G 155 2005a PRf Construction•MateriafsTechnotogies(TST6049)• NEF093-02-02 ASTIUf D 1:970 2009 PRI Construction Materials Technologies(TST6049) OCF-213-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies(TST6049) OCF-237-02-01 UL 1897 2004 PRI Construction Materials Technologies(TST5&7&) 0CF-252-02-01 ASTM D 4798 2001 PRI Construction Materials Technologies(TST6049) OCF-252-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST5878) OCF-253-02-02 ASTM D 1970 2009 PRi Construction Materials Technologies(TST6049) OCF 272-02-01 TAS 103 1995 PRODUCT DESCRIPTION AND LIMITS OF USE Weathe&ackO+G WeatherLock@ G is ars.ASTM D 1970-self-adhesive asnderlayment constructed from SBS modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product-is supplied in 2=sq. rolls witty nominaldimensions of 34x-66.7-ft WeatherLock@ G is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate roofing as prescribed in the FBG. Exposure on the roof deck shalt be limited to a maximum 30.days. WeatherLock@ Mat WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- sq..rolls with.nominal dimensions.of 3-11.x 33.3-ft and 2 sq.rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock(Mat is,permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles,and slate roofing as prescribed in the FBC_ Exposure on the roof deck shalt be limited to a maximum 30 days. OCR14002.4A FL9777-R7 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use; or other product attributes that are-not specifically addressed herein. G OWENS CORNING ROOFING AND ASPHALT LLC UlleatherLock®Self-Sealing Ice&Water Barriers TECHNICAL SERVICES, LLC WeatherLock@ Metal WeatherLock@ Metal is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ Metal is permitted to be used with mechanically fastened asphalt shingles, metal roof panels or shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock@ WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment Specialty Tile&Metal constructed from SBS modified asphalt and surfaced with a non-woven polyester fabric. Tfie product is supplied in 2.14 sq.Tolls with nominal dimensions of 3-ft x 71.3 ft. WeatherLock@ Specialty Tile&Metal is permitted to be used with mechanically fastened asphalt shingles, clay or concrete tile, metal roof panels or shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. WeatherLock@ Specialty Tile & Metal is permitted to be used with adhered clay or concrete the roofing using either 3MTM 2-Component Foam Roof Tile Adhesive AH-160(3M Company)or TILE BONDTTM Roof Tile Adhesive(The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 files per stack. PRODUCT APPLICATION Min.Roof Slope: 2:12 or in accordance in with FBC Application: Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck.The underlayment shall be installed With the roll length parallel to the eave, starting at the eave, and with minimum 3" side laps and minimum 6° end laps staggered 6-ft. -from preceding course. End laps for WeatherLock@ Specialty Tile& Metal shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It is permissible to nail the underlayment 18-inches on-center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). WeatherLock@ Specialty Tile & Metal shall be back naffed when installed on roof slopes greater than 3:12. For valley applications, the roll shall be applied centered along the valley prior to installing the underlayment at the eave. For eave protection, the underlayment should extend to a point 24-inches inside the exterior wall. The underlayment shall be installed over metal drip edge at the eave,and under the drip edge at the rake or valley pan when used as a valley liner. Alternately, it is permissible to install-the underlayment underthe drip edge in accordance Section 1507.2.9.3. Min.Application 40°F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. OCR14002AA FL9777-R7 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20 3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. CRK OWENS CORNING ROOFING AND ASPHALT LLC 1KeatherLock&Sett-Sealing Ice&Water Barriers TECHNICAL SERVICES, LLC WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBG Section 1504.9. Underlayment System No.1 Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c. Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with manufacturer's installation instructions to the fastened deck and backnailed along the selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through optionally primed 32ga. x 1-5/8-inch .0 tin caps spaced 12" -o.c. The applied underlayment shall be rolled with a minimum 751b steel roller immediately following application. Maximum Design -105 psf Pressure: GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance. with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. OCR14002AA FL9777-R7 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GREEK OWENS CORNING ROOFING AND ASPHALT LLC Vlleatherl-ock®Self-Sealing Ice&Water Barriers_ TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code Edition(2014)as evidenced in the referenced documents submitted by the named manufacturer. R. 2 016.04.19 Wo 74021 (_. 15:51 :11 * = -04r00r STATE OF 'CT� 'c P••'��: Zachary R. Priest,P.E. Florida Registration No.74021 �i����0►�p6 % Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14002AA FL9777-R7 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.