HomeMy WebLinkAboutProduct Approval7/8/2016
Florida Building Code Online
@_�•, BCIS Home Log Ir User Registration Hot Topics - Submit Surcharge Stats & Facts i Publications FEC Staff 1 BCIS Site Map Links Search
Business.°" `,
ProfeProfessional Product Approval
ssional USER: Public User
tlr^:.�r,rua,�„r,r.•ihdu Product Auorovai Menu > Product or ADDLCatim search > Anoiication List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Testing Lab
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL15529-R1
Revision
2014
Approved
IKO Industries, Ltd
40 Hansen Road South
Brampton, NON -US L6W 3H4
(708) 496-2800 Ext 200
rmetzDO1@tampabay.rr.com
Robert Metz
rmetzGD1@tampabay.rr.com
Bob Metz
REMCO of Pinellas
456 Avila Circle NE
Saint Petersburg, FL 33703
(727) 776-5261
rmet7OOl@tampabay.rr.com
Don Shaw
IKO Industries LTD
120 Hay Rd.
Wilmington, DE 19808
(717) 579-6706
don.shawLaiko.com
Roofing
Underlayments
Test Report
PRI Construction Materials Technologies, LLC
Keystone Certifications, Inc.
06/26/2025
Zachary R. Priest, P.E.
Validation Checklist - Hardcopy Received
FLIS529 R1 COI FL12838 R2 COI PRI CMT Cert of Indeoendencefll.ndf
FL15529 Rl COI FM - Certificate of Independence 3-25-2011.odf
Standard
01970
Year
2009
hftps:llwww.flori dabui I di ng.org/pr/pr_app_dtl,aspx?param=wC3EVXQwtDgvKm QdI DUtQtIXdgH l6aA.W g7ZYips%2fluk8a6ZyM dl6clg°/`3d%3d 112
7/8/2016
Product Approvaf Method
Florida Building Code Online
Method 1 Option B
Date Submitted 06/29/2015
Date Validated 07/14/2015
Date Pending FBC Approval 07/23/2015
Date Approved 10/16/2015
Summary of Products
FL # Model, Number or Name Description
i
15529.1 StormShield Standard Ice and #7910033
Water Protector
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL15529 R1 II SShieidlWO806 ADDIICation Instructions
Approved for use outside HVHZ: Yes
2012.odf
Impact Resistant: N/A
Verified By: PRI Construction Materials Technologies, LLC
Design Pressure: N/A
Test Reports
Other:
FL15529 R1 TR IKO-081-02-01 ReoortASTM D 1970
StormShield Standard Ice and Water Protector 04-2012
to l.pdf
FL15529 R1 TR IKO-143-02-01 FBC 2014 Letter - FBC
FL15529.odf
m
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: B50-487-1824
The State of Florida is an AA/FEO employer. Convriaht 2097-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in resporse to a public -records request, do not send electroric
mail to this entity. Instead, contact the office by phone or by traditional mail, If you have any questions, please contact 650.467.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one, The enr its provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which ran be made available to the public, To determine if you are a licensee under Chapter
455, F.S., please click here ,
Product Approval Accepts:
® Ei3{N
S%ti iIt'It �: I1- i'ttiE �'
https://www.floridabuilding.orglprtpr_app dtl.aspx?param=wGEVXQwtDgvKmQdIOUtQtlXdgH 16aAWg7ZYjps%2nuk8a6ZyMdl6clg%3d%3d 212
mi
CONSTRUCTION
MATERIALS
TECHNOLOGIES
Brad Grzybowski
Managing Director
July 9, 2015
Dear Sir/Madam,
PRl-CMT tested several products for IKo Industries and subsequently issued LaboratoryTest Reports. These
reports have been utilized to support FL15529. This letter serves to establish compliance of legacy test reports
to FBC 2014.
FL15529 — StormShield Standard Ice and Water Protector
Product Specification
41 Applicable product specification: ASTM D1970
• FBC 2014 referenced standard year: ASTM D1970-09
• Test Report: PRI Project/Report Number 1KO-08102-01 states compliance to ASTM D1970-08.
• Action: Establish equivalency between ASTM D1970-08 and ASTM D1970-09.
• Conclusion: Compliance to FBC 2014 established.
Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E. do not
have nor plan to acquire a financial interest in any company manufacturing or distributing products for which
the test reports are issued.
Signed:
Brad Grrybo� ski
Managing Director
Date:
IKO-143-02-01
July 9, 2015
Signed: f
Duc T.I u en
Florida Reglgierer`f Professional Engineer
P.E. Number: 65034
Date:
July 9, 2015
PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa. FL 33610 Tel: 813-621-577T Fax: 813-621-5840 e-mail: materialstesting@pricmt.com WebSite: http11www.pdrmt.cem
APPLYING lKO'S STORMSHIELD
ICE &WATER PROTECTOR
Caution
• Read all instructions before proceeding with application.
• Membrane must always be covered by shingles or other roofing materials. It must not be left exposed
to the weather.
• This product is a vapour retardant. Space under roof deck must be properly ventilated to avoid
moisture condensation.
• In cool temperatures membrane should be tacked in place with mechanical fastenings.
• Installation is not recommended when air and substrate surface temperatures are less than 5°C (40°F).
APPLICATION DIRECTIONS
Surface Preparation
• The roof deck must be clean, smooth, dry and free of sharp protrusions.
• Metal and masonry surfaces must be primed.
Installation
1. Cut the membrane into 3 m to 4.5 m (10 ft. to 15 ft.) lengths.
2. Unroll and align with the lower edge of roof. Tack top edge with four equally -spaced temporary
fasteners.
3. Lift the lower half and remove the lower release film, exposing the adhesive surface.
4. Carefully reposition the membrane down onto the deck and press firmly in place. Avoid wrinkles.
Remove temporary fasteners.
5. Fold top half down and remove release film.
6. Carefully reposition the membrane up onto the deck and press firmly in place. Avoid wrinkles.
• If two courses are required, the top course should overlap the selvage tape on the lower course by
75 mm (3").
• End laps must be at least 15 cm (6") and rolled to ansure adhesion and should be located at least 61
cm (24") from those in the previous course.
• Apply each course carefully.
• Best suited for low sloped roof areas. Cover entire area with StormShield Standard Ice and Water
Protector, lapped as outlined above, and then shingle as per normal shingle exposures.
Valleys and Ridges
• Cut the membrane into 1.2 m to 1.8 m (4 ft. to 6 ft.) lengths. In the valley, start at the low point and
work upwards, overlapping each sheet at least 15 cm (6"). Peel off the release film and centre the
sheet over the valley or ridge. Drape and press in place working from the centre outward toward the
edges.
• Membranes must not be left exposed in an open valley.
Ice Dam Protection
• Membrane must be applied to reach above the highest expected level of ice dams, and at least 61 cm
(24") up the roof from the vertical projection of the interior surface of the outside wall.
Drip Edge
• Drip edges must be located under the membrane at the eaves, and over the membrane at rake edges
Note
• Do not remove selvage tape.
Storage
• Store rolls in their carton until application. Store inside or under cover not over 40°C (104°F).
SShieldlW 08-06
6� •Y . •lYr Y r —•�.
1 r �
t � r',.���f1%i i J%Y.,�.♦r Ir
. � • ` •fir 'r
J
■YVr�.
f� J
• d �- Y
• � • - Y •r Y 4
• SShieldlW 08-06