HomeMy WebLinkAboutSun Tek- ISFG -Self Flash Glass SkylightMIAMI•DADE IYIiAMI-DARE COUNTY all 1� PRODUCT CONTROL SECTION DEPARTMENT.OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) vww.miamidade.eov/econ_omv Sun -Tek Manufacturing, Inc. 10303 General Drive Orlando, FL 32824 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ISFG Skylight System APPROVAL DOCUMENT: Drawing No. STI -00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun -Tek Manufacturing, Inc., dated August 07, 2007, last revision #A dated May 04, 2015, signed and sealed by James D. Wells, Jr., P.E., on May 04, 2015, bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and the expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series and the following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official, This NOA revises NOA ## 13-1028.05 and consists of this page 1, evidence submitted pages E-1, E-2, & E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Hle/lmy A. Makar, P.E., M.S. NOA No. 15-0513.10 MIAMI•DAOE COUNTY , f �J4clwl_� Expiration Date: 10/31/2018 oq l D3�Za JS Approval Date: 09/03/2015 Page 1 Sun -Tek Manufacturing. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #07-0425.04 A. DRAWINGS 1. Drawing No. STI-00000298-SHTIISHT2, titled "ISFG ", sheet I & 2 of 2, prepared by Sun -Tek Manufacturing, Inc, dated 06104107 with last revision dated 08107107, signed and sealed by James D. Dells, Jr., P.E. B. TESTS (submitted under NOA # 02-0618.06) 1. Test Report on Large .Missile .Impact Test per PA 201, Cyclic Wind Pressure Test per PA 203 and Uniform Static Air Pressure Test per PA 202 of "Insulated Glass Skylight with Polycarbonate Inner Liner" prepared by National Certified Testing Laboratories, Report No. 210-2760-1, 2 & 3, dated 01122102, signed and sealed by B. Portnoy, P.E. C. CALCULATIONS 1. Anchor Calculations for attachment _of skylight to curbing and curbing to decking, dated 08113107, signed and sealed by James D. Wells, Jr., P.E. D. MATERIAL CERTIFICATIONS (submitted under NOA # 02-0618.06) 1. Test report on Rate of Burning per ASTMD635 of Geon 87416 White 141 Exterior, 0.137 inch, prepared by Commercial Testing Company, Report No. 01- 11293, dated 11129101, signed by J Jackson. 2. Test report on Self Ignition Temperature per ASTMD1929 of Geon 87416 White 141 Exterior, prepared by Commercial Testing Company, Report Aro. 01-11292, dated 11129101, signed by J Jackson. E. STATEMENTS (submitted under NOA # 02-0618.06) 1. Code compliance letter issued by Product Technology Corporation. on 09127102, signed and sealed by R. J. Quiroga P.E. F. OTHER 1. NOA renewal request letter issued by Sun -Tek Manufacturing, Inc., dated 08116107, James Feudner. 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #11-0601.02 A. DRAWINGS 1. Drawing No. STT 00000298-SHTIISHT2, titled "ISFG ", sheet I & 2 of 2, prepared by Sun -Tek Manufacturing, Inc, dated August 07, 2007, last revision #A dated October 14, 2011, signed and sealed by James D. Wells, Jr., P.E. Yt / elmv A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 15-0513.10 Expiration Date: 10/31/2018 Approval Date: 09103/2015 E-1 Sun -Tek Manufacturins, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED, B. TESTS 1. Test Addendum for Test Report NCTL 210-2760-1, prepared by national Certified Testing Laboratories, dated October 17, 2011, certifying the interlayer thickness, signed by Mark Bennett, Manager of Testing Services. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Permitting, Environment, and Regulatoty Affairs (PERA). E. MATERIAL CERTIFICATIONS 1. None. 3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #12-1011.15 A. DRAWINGS 1. Drawing No. STI -00000295, titled "ISFG", sheet I & 2 of 2, prepared by Sun -Tek Manufacturing, Inc, dated August 07, 2007, last revision #A dated May 03, 2012, signed and sealed by James D. Wells, Jr., P.E. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL. CERTIFICATIONS 1. None. F. OTHERS 1. A compliance letter, prepared by J & L Wells Consulting LLC, dated April 25, 2012, certify compliance with FBC 2010 edition, sign & sealed by James D. Wells, Jr., P.E. 2. Verification testing to be performed per letter from National Certified Testing Laboratories, dated September 18, 2012, signed by Christopher Bennett. Helmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 15-0513.10 Expiration Date: W31/2018 Approval Date: 09/03/2015 E-2 Sun -Tek Manufacturine, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED. 4. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 13-1028.05 A. DRAWINGS 1. Drawing No. STI -00000298, titled "ISFG", sheet I & 2 of 2, prepared by Sun -Tek Manufacturing, Inc., dated August 07, 2007, last revision #A dated August 15, 2013, signed and sealed by James D. Wells, Jr., P.E., on February 07, 2014. B. TESTS 1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test -per PA 203 and Uniform Static Air Pressure Test per PA 202 of "Insulated Glass Skylight with Polycarbonate Inner Liner" prepared by National Certified Testing Laboratories, Report No. 210-3915-01, dated 0812712013, signed and sealed by Gerard Ferrara, P.E. C. CALCULATIONS 1. Anchor Calculations for attachment of skylight Model ISFG to Decking, dated 1010312013, signed and sealed by James D. Wells, Jr., P.E. D. QUALITY ASSURANCE 1. By .Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. Bill of Material and Components Die Drawings. 5. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. STI -00000298, titled "ISFG", sheet I & 2 of 2, prepared by Sun -Tek Manufacturing, Inc., dated August 07, 2007, last revision M dated May 04, 2015, signed and sealed by James D. Wells, Jr., P.E., on May 04, 2015. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1, By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. tT elmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 15-051.3.10 Expiration Date: 10/31/2018 Approval Date: 09/03/2015 E-3 PART NAME: ISFG SKYLIGHT ASSEMBLY FILE NAME: Z:1DWG1DWGIACAD 2000 DRAWINGSIDADE COUNTY ISFG STI -00000298 STI -215 DECO COVER 0.075 6063 T6 ALUM 17132" GLASS BITE 1/8" OUTBOARD DSB TEMPERED SILICONE BEDDING (CONTINUOUS) 118" INBOARD GLASS RSB TEMPERED STI -6 GLASS GASKET EPDM n) (CONTINUOUS)r INSULATED AIR SPACE � ARGON GAS FILLED STi-401 WOOD LINER 1.16x0.935" j (CONTINUOUS) SWIGGLE SPACER(0.6,?5) #8-32 PHILLIPS PAN HD SCREW AND HEX NUT 7 PER LONG SIDE 7 PER SHORT SIDE I i —� 177 POLYCARBONATE SHEET PALRAM PALSUN LL BUTYL 3 RINGS OF SEALANT a CONTINUOUS BENEATH FLANGE STI -300 PVC LINER (CONTINUOUS) GEON 87416 WHITE w O AROUND PERIMETER OF FLANGE 141 EXTERIOR —� 0 w (CONTINUOUS) AND ON TOP OF EACH z FLANGE SCREW Q AIR SPACE OR DADE COUNTY APPROVED co SHINGLES EXPANDED POLYSTYRENE INSULATION (SEE NOTE 1) Y ��--- ROOF DECK min.8" thick DESIGN PRESSURE RATING+/- 80 PSF. LARGE MISSILE IMPACT RESISTANCE Engineer of Record , James D. Wells, Jr.,P.E. Professional Engineer No. 53616 NOTE: ` * (1) ALL ROOFING DETAILS SHALL COMPLY WITH nu n r)-Mrl 4 G PIC -rUr- c1 P\OInA 01 Ili M1?%1('_ (`nnC 7f)l it nrlifir PART NAME: ISFG SKYLIGHT PLAN VIEW I FILE NAME: Z:\DWG\DWG\ACAD 2000 DRAWINGSXDADE COUNTY ISFG STI -00000298 NOTE: 3 1, . . (1) ALL ROOFING DETAILS SHALL COMPLY WITH Professional Engineer No. 53616 r1UA0'rr_0 1r, ni: -rWC: M nD1r1A ni ni nw(,_ (,r)nr: onlA arfifinn PRODUCTREVISF-L 54.5 STI -214 DECO R tito tip 4.000 5.8125p 4.000— SILICONE BEE 5.8125 5.8'; 25 5.3125 STI -6 GLA; STI -41 — - -- - - " — ¢ STI -205 CMG FRAME 0.06( D CORNER f } 3. #8-32 X 4' PHILLIPS CD AND HEX N FASTENERS SKYLIGHT AND BOTT TO DECK #8 X 1" (9) PER SIDE 0 ST 1-20' AP LL oil ISFG 4949 w 0 0 3 R11 :�i BENEA1 =) uJ z 0 AROUN < u- (CONTINUO SYME-RICAC I,.- LO DQ� 0 :: U) SH (SE 0 #8 X T' PHILPS PA9 FASTENERS SUB -FRAME TO FRAME SCREW (9) PER t " I y I I - Al min- protr C) ROOF DEi 4" MININUM LIP C) ROOF SURFA( DESIGN PRESSURE RATING+]- 80 PSF. 0 LARGE MISSILE IMPACT RESISTANCE Engineer of Record jompe In IA/rdle Jr P 1= NOTE: 3 1, . . (1) ALL ROOFING DETAILS SHALL COMPLY WITH Professional Engineer No. 53616 r1UA0'rr_0 1r, ni: -rWC: M nD1r1A ni ni nw(,_ (,r)nr: onlA arfifinn PRODUCTREVISF-L