Loading...
HomeMy WebLinkAboutBuilding Permit Application (2) Florida$uilding Code Online Page 1 of 5 Businessk Profession Regulation, BCIS Home Login I User Registration Hot Topics Submit Surcharge Stats&Facts Publications I FBC Staff I SCIS Site Map I Links Search ba- Product Approval 1 I . USER:Public User V"3NntdB - i Product Approval Menu>Product Application Search>Application List>Application Detail' r FIL FL14911-R7 - Application Type Revision Code Version 2014 Application Status Approved i Comments Archived ❑ Product Manufacturer Silverline Building Produits Corp. Address/Phone/Email. .. One Silverline Drive. North Brunswick,.NJ 089,02 (800)23474228. Ext 46'44 Jonberrian@slbp.com a Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative ' Jon Berrian Address/Phone/Email One Silverline Drive North Brunswick,NJ 08902 (732)435=1000 1 jonberrian@slbp.com Y Quality Assurance Representative �I Address/Phone/Email I Category 'Windows Subcategory Single Hung Compliance.Method Evaluation Report from a Florida Itegisteretl Architect or a Licensed Florida Professional Engineer Evaluation Report-'Hardcopy Received Florida Engineer or.Architect Name who developed Lyndon F.Schmidt,P.E., the Evaluation Report Florida License PE-43409 Quality Assurance.Entity Window and Door Manufacturers Association-QA Quality Assurance Contract.Expiration Date 08/03/2021 Validated By, Ryan J.King,P.E. 0 Validation Checklist,',Hardcopy Received Certificate of Independence FL14911 R7 COI Certificate Of Independence(2).ndf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA/101/I.S.2/A440 2008 AAMA/WDMA/CSA/101%I.S.2/A440 2011 . ASTM D1929 1996 ASTM D2843 1993 ASTM D635 1996 ASTM D638- 1996 ASTM E1886 2005 ASTM E1996 2009 ASTM G26 1995 -TAS 201,202 and 203, 1994 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquZRj 59%2fDrx.... . 1/4/2017 Florida Building Code Online Page 2 of 5 Equivalence of.Product Standards "Certified By Florida Licensed Professional Engineer or Architect FL14911 R7 Ecuiv Equivalency Of Standards Ddf Sections from the Code Product Approval Method Method 1 Option D P Date Submitted 04/02/2015 Date Validated 04/13/2015 Date Pending FBC Approval 04/16/2015 Date Approved 06/23/2015 Summary of Products Go to Page t3'd Page 1/2 FL# Model,Number or Name Description 14911.1 a.S 2900/4900-M 2901/4901 Single Hung Extruded Vinyl Window with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 iII Inst 14911.1.0f Approved for use outside.HVHZd Yes Verified By: Lyndon F. Schmidt,,P.E.43409' Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 14911.1 for Design Pressure Ratings,any FL14911 R7:AE Eval 14911.1.6df additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 14911.2 b. S 2900/4900-M 2901/4901 "Oriel"Extruded Vinyl Single Hung Window with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7:111 Inst 14911.2.Ddf Approved for use outside.HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 14911.2 for Design Pressure Ratings,any FL14911 R711AE Eval 14911.2.�df additional use limitations,installation instructions and Created by Independent•Third Party:Yes product particulars. 14911.3 c.Series 2900/4900 Models Single Hung Extruded Vinyl Window with Nailing Fin 2901/4901"Weather Stopper" " Limits of Use Installation Instructions Approved for use.in HVHZ:No. FL14911 R7'II Inst 14911.3.pa Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes' Design Pressure:N/A Evaluation Reports Other:See INST.14911.3 for Design Pressure Ratings,any FL14911 R7 AE Eval 14911.3.pdf additional use limitations,installation instructions.and Created by Independent Third Party:Yes product particulars. (Note-See 14911.24 for Wind Zone 4 and HVHZ Impact Product) 14911.4 d.S 2900/4900-M 2902/4902 Twin-Single Hung Continuous Head and_Sill Extruded Vinyl - Window.with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R71 II Inst 14911.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.:Schmidt,P.E.43409, Impact Resistant:No Created,by Independent Third Party:Yes Design Pressure: N/A EvaluationReports Othen See INST:14911.4 for Design Pressure Ratings,any FL14911 R7 AE Eval 14911.4.odf additional.use limitations,installation instructionsand Created by Independent Third Party:Yes product particulars. 14911.5 e.S 2900/4900-M 2903/4903 Triple-Single Hung Continuous-Head and Sill Extruded Vinyl Window with Nailing Fin Limits of Use Installation lInstructions Approved for.use in HVHZ:No., FL14911 RT II Inst 14911.5.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt;P.E.43409 Impact Resistant:No Created_by Independent Third Party:Yes Design Pressure:N/AEvaluation Reports Other:See INST 14911.5 for Design Pressure Ratings,any FL14911 R7 AE Eval 14911.5.Ddf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquZRj59%2fDrx... 1/4/2017 Florida Building.Code Online Page 3 of 5 . . 14911.6 f. S 2900/4900-M 2901/4901 Single Hung Extruded Vinyl Window-Flange with Strap Anchor on Sill'' Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 II Inst 14911.6.odf Approved for use outside HVHZ:Yes Verified By: Lyndon.F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 14911.6 for Design Pressure Ratings,any FL14911 R7 AE Eval 14911.6.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 14911.7 g.S 2900/4900-M 2902/4902 Twin.-Single Hung Continuous Head and Sill Extruded Vinyl Window-Flange with Strap Anchor on Sill Limits of Use Installation Instructions Approved"for use in HVHZ:No FL14911 R7 III. INST 14911.7.odf. Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,.P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:This Product is No Longer Offered by Silverline FL14911 R7!AE EVAL 14911.7.odf Building Products,Corporation(See 14911.7-2010 FBC Created;by Independent Third Party:Yes version for Historical.Documents regarding this Approval) 14911.8 h.S 2900/4900-M 2903/4903 Triple-Single,Hung Continuous Head and Sill Extruded Vinyl Window-Flange with Strap Anchor on Sill Limits of Use Installation Instructions Approved for.use-in,HVHZ:No FL14911 R7'II INST 14911.8.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:This Product is No Longer Offered by Silverline FL14911 R7 SAE EVAL 14911.8.0f Building Products,,Corporation(See 14911.8-2010 FBC Created.by Independent Third Party:Yes .version for Historical Documents regarding this Approval). 14911.9 L Series 2900/4900 Models Extruded:Vinyl'Single Hung Window 2901/4901"Weather-Stopper" Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 41 Inst 14911.9.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 14911.9 for Design Pressure Ratings,any FL14911 0 AE Eval 14911.9.odf roduct articulars. Note-See 14911:25 for Wind Zone 4 . ?. dependentThird Party:Yes additional use limitations,installation instructions and Createdby Ini p P (. and HVHZ Impact Product)' . 14911.10 j.Series 2000/Model 2001 ExtrudedVinyl,Single Hung Window Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 117:11 Inst 14911.10.odf Approved for.use outside HVHZ:Yes: Verified By: Lyndon F.Schmidt,P.E.43409 - Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A. Evaluation Reports Other:See INST 14911.10 for Design.Pressure Ratings, FL14911 R7'AE Eval 14911.10:pdf any additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14911.11 _ . - k.Series 2000/.Model 20,012 Extruded Vinyl Twin Single.Hung Window(Continuous Head and Sill with Integral Mullion) Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7'III Inst 14911.11.odf Approved for use outside HVHZ:-Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 14911.11 for Design Pressure Ratings, FL14911 R7 AE Eval 14911.11.odf any additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 1491-1.12 I.Series 2000/Model 2003 Extruded Vinyl Triple Single Hung Window(Continuous Head arid Sill with Integral Mullion) Limits of Use Installation Instructions Approvedforuse in HVHZ:No FL14911 R7^11 Inst 14911.12.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,.P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes' Design Pressure:N/A. -; Evaluation Reports Other:See INST 14911.12 for Design Pressure Ratings, FL14911 R7 AE Eval 14911.12.odf any additional use I'imitatlons,installation instructions and Created by Independent Third Party: Yes product particulars. https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquZRj 59%2fDrx... 1/4/2017 Florida Building,Code Online Page 4 of 5 14911.13 m.Series 2100/Model 2111 Extruded Vinyl,Single.Hung Window-Flange Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 II. Inst 14911.13.odf Approved.for use outside HVHZ:Yes Verified By: Lyndon F..Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.13 for Design Pressure Ratings, FL14911 R7 'AE Eval 14911.13:odf any additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 14911.14 n.Series 2200/2300-Model Extruded Vinyl Single Hung Window-Nailing Fin 2201/2301 1' Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 SII Inst 14911.14.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:.No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports. -'. Other:See INST 14911.14 for.Design Pressure Ratings, FL14911 R7 AE Eval 14911.14:odf any additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 14911.15 o.Series 2200/2300-Model Extruded Vinyl,Twin Single Hung Window-Nailing Fin 2202/2302 (Continuous Head and Sill with Integral Mullion) Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 II Inst 14911.15.odf Approved for use outside HVHZ:Yes Verified By: Lyndon-F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent.Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.15 for Design'Pressure:Ratings, FL14911 R7 AE Eval 14911.15:odf any additional use limitations, installation instructions and Created by Independent'Third Party:Yes product particulars. 14911.16 p.Series 2200/2300-Model Extruded Vinyl,Triple Single Hung Window-Nailing Fin 2203/2303 (Continuous Head and Sill with Integral Mullion) Limits of Use Installation Instructions Approved for use in HVHZ:No F04911 R7 II Inst 14911.16.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.16 for Design Pressure Ratings, FL14911 R7 iqE Eval 14911,16.1[)df . any additional use limitations,installation instructions and '. Created by In'dependentThird Party:Yes product particulars. II 9 14911,17 q.Series 2907 Model 2907 Single Hung Extruded Vinyl Window with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 II Inst 14911.17.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F:Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 14911.17 for Design Pressure Ratings, FL14911 R7 iAE Eval 14911.17.Ddf any additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14911.18 r.Series 2907 Model 2907TW Twin-Continuous Head&Sill Single Hung Extruded Vinyl Window with Nailing.Fin Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 'R7 II Inst 14911.18.Ddf Approved for.use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created.by IndependentThird Party: Yes Design.Pressure:N/A Evaluation Reports,. Other:See INST 14911.18 for Design Pressure Ratings, FL14911 R7 AE-Eval 14911.18.odf any additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 14911.19 s.Series 2907 Model 2907TR Triple-Continuous.Head&Sill Single Hung Extruded Vinyl Window with Nailing.Fin Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 II Inst 1491,.19.odf Approved for use.outside HVHZ:Yes Verified By: Lyndon F.Schmidt;P.E.43409, Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports ' Other:See INST 14911.19 for Design Pressure Ratings, FL14911 R7 IAE Eval 14911.19.odf any additional use limitations,installation instructions and Created by In'dependeritThird Party:Yes product particulars. 14911.20 t.Series 70 Model 2127 Extruded Vinyl Single Hung Window-Nailing Fin https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquZRj 59%2fDrx... 1/4/2017 Florida Building Code Online Page.5 of 5 . Limits of Use Installation Instructions Approved for use in HVHZ:Yes' FL14911 R7 II-Inst 1491 20.6df Approved.for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,:P.E.43409 Impact Resistants No Created:b In p9 / y dependent Third Party: Yes : Desi n Pressure:.NA Evaluation Reports Other:See INST.14911.20 for Design Pressure Ratings; FL14911 R7,AE Eval 14911.20.Ddf any additional use limitations,installation instructions and ., Created:by Independent Third Party: Yes product particulars. - Go to Page Page;1/.2 . . Back Next - . . . . . . . Contact'Us:::2601 Blair Stone Road.Tallahassee FL 32399 Phone,850-487-1824 - The State of Florida is:an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy St tement .Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If youAo not want your e-mail address released in response to a public-records.request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail:If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S;must provide the Department with an email address if - they have one.The emails.provided.may be used for official communication with the licensee.However email addresses are public record.If you do not wish to. - - : supply a personal address,please provide the Department with an email address which can be made available to the public.To'ldetermine if you are a licensee under Chapter 455;F.S.,please click here. - - - Product Approval Accepts: Credit Card. Safe . https://www:floridabuilding..org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquZRj 59%2fprx... 1/4/2017,